Troubleshooting
30
3A6165J
L6TB
Blue Auto Refill
Timeout
No material is actually being fed
Make sure the feed pumps are
operating properly
Loose level sensor connection
Check for loose or disconnected
wires or plugs
Bad level sensor
Replace level sensor
MAA0
Pump A Cycles
Exceeds Limit
Setting
The number of Pump A (or B) cycles
has exceeded the limit entered on
the Setup Maintenance 1 screen
Raise or enter 0 in the
corresponding cycle counter limit.
Set the corresponding Pump or
Dispense Valve counter to 0.
MAB0
Pump B Cycles
Exceeds Limit
Setting
MED1
Dispense Valve
Cycles Exceeds
Limit Setting
The number of Dispense Valve
cycles has exceeded the limit
entered on the Setup Maintenance 1
screen
P1DA
Low Pressure Alarm
Outlet A
Pressure A is below user-defined
dispense pressure limit
Check feed system for low or empty
material.
Increase dispense rate.
Check pressure settings on setup
screen.
P1DB
Low Pressure Alarm
Outlet B
Pressure B is below user-defined
dispense pressure limit
Check feed system for low or empty
material.
Increase dispense rate.
Check pressure settings on setup
screen.
P1FA
Low Pressure Alarm
Inlet A
Pressure A is below user-defined
dispense pressure limit
Check feed system for low or empty
material.
Check feed system filters for
blockage if installed.
Check for blockage in feed system.
Check pressure settings on setup
screen.
P1FB
Low Pressure Alarm
Inlet B
Pressure B is below user-defined
dispense pressure limit
Check feed system for low or empty
material.
Check feed system filters for
blockage if installed.
Check for blockage in feed system.
Check pressure settings on setup
screen.
Error Code
Code Description
Cause
Solution