Troubleshooting
34
3A6165J
P4FB
High Pressure
Alarm Inlet B
Pressure B exceeds user-defined
dispense pressure limit.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
P6DA
Pressure Sensor
Error Outlet A
Loose or bad sensor connection to
Motor Control Module
Check to make sure that the
pressure sensor is properly
connected to connector 6 of the
Motor Control Module (MCM)
Faulty sensor
Replace the Pressure Sensor
P6DB
Pressure Sensor
Error Outlet B
Loose or bad sensor connection to
Motor Control Module
Check to make sure that the
pressure sensor is properly
connected to connector 5 of the
Motor Control Module (MCM)
Faulty sensor
Replace the Pressure Sensor
P6FA
Pressure Sensor
Error Inlet A
Loose or bad sensor connection to
Motor Control Module
Check to make sure that the
pressure sensor is properly
connected to the connector 6 of the
Fluid Control Module (FCM).
Faulty sensor
Replace the Pressure Sensor
P6FB
Pressure Sensor
Error Inlet B
Loose or bad sensor connection to
Motor Control Module
Check to make sure that the
pressure sensor is properly
connected to connector 5 of the
Fluid Control Module (FCM).
Faulty sensor
Replace the Pressure Sensor
P7DA
Pressure Imbalance
High A
Dispense line is clogged
First try purging fresh material
through the system. Then relieve
pressure and check for cured
material or obstructions in the
dispense valve.
Orifice restrictions sized incorrectly
Adjust orifice restrictions to balance
pressure of A and B materials
Out of material
Verify B material supply
Pressure imbalance is defined too
low
Increase pressure imbalance
amount from the Setup screen of the
Advanced Display Module (ADM)
Error Code
Code Description
Cause
Solution