Troubleshooting
3A6165J
31
P2DA
Low Pressure
Deviation Outlet A
Pressure A is below user-defined
dispense pressure limit
Check feed system for low or empty
material.
Increase dispense rate.
Check pressure settings on setup
screen.
P2DB
Low Pressure
Deviation Outlet B
Pressure B is below user-defined
dispense pressure limit
Check feed system for low or empty
material.
Increase dispense rate.
Check pressure settings on setup
screen.
P2FA
Low Pressure
Deviation Inlet A
Pressure A is below user-defined
dispense pressure limit
Check feed system for low or empty
material.
Check feed system filters for
blockage if installed.
Check for blockage in feed system.
Check pressure settings on setup
screen.
P2FB
Low Pressure
Deviation Inlet B
Pressure B is below user-defined
dispense pressure limit
Check feed system for low or empty
material.
Check feed system filters for
blockage if installed.
Check for blockage in feed system.
Check pressure settings on setup
screen.
P3FA
High Pressure
Deviation Inlet A
Pressure A exceeds user-defined
dispense pressure limit.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
P3FB
High Pressure
Deviation Inlet B
Pressure B exceeds user-defined
dispense pressure limit.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
P3FC
High Pressure
Deviation Inlet A
Pressure A exceeds user-defined
dispense pressure limit.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
P3FD
High Pressure
Deviation Inlet B
Pressure B exceeds user-defined
dispense pressure limit.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
Error Code
Code Description
Cause
Solution