I/O Integration
62
3A6165J
If the sequence is not in operator mode, a pulse on the trigger pin will result in the sequence being played.
Sending the sequence select bits is optional. If the sequence select bits are not sent, the EFR will use the current
selected sequence.
If a shot is in operator mode throughout a sequence, the EFR will only dispense that shot if the trigger pin is ON.
Once the trigger pin is OFF, the EFR will continue to the next shot in the sequence.
Automation Inputs (EFR Outputs)
System Ready
Alarm Active
Valve Signal
Automation Outputs (EFR Inputs)
Trigger Signal (Foot Switch)
System Enable
Sequence Select Bits (optional command)
EFR State
Sequence Running
Key
EFR Sequence is running
EFR Discrete Signal Run Sequence
Automation Inputs (EFR Outputs)
System Ready
Alarm Active
Valve Signal
Automation Outputs (EFR Inputs)
Trigger Signal (Foot Switch)
System Enable
Sequence Select Bits (optional command)
EFR State
Sequence Running
Key
EFR Sequence is running in Operator Mode
EFR Discrete Signal Run Sequence in Operator Mode
Analog Flow Rate Set Point Command can be
used to modify flow rate on the fly