ADM Screen Overview
48
3A6165J
Index Menu
From the home screen, press the
button to
access the index. This screen provides access to
Sequence Definition, Setup, Advanced, Maintenance,
Shot Log, Events, Errors, and Integration screens.
Sequence Definition Screen 1
This screen allows users to create and edit sequences.
From here, users are able to edit the flow rate, shot size
and calibration of individual shot sizes in a selected
sequence. There are four options available for the shot
size, including operator mode, volume, mass/weight and
seconds.
NOTE:
If the user selects seconds for the shot size, cal
-
ibration will no longer be an option for the selected shot
size.
NOTE:
If the user selects operator mode for the shot
size, the EFR will only dispense at the desired flow rate
as long as an external trigger source or foot switch is
active for that particular shot of the sequence.
NOTE:
If the flow rate is set to zero, the EFR will wait for
the specified amount of time before performing the next
shot size.
New shot sizes can be added to a sequence by pressing
, which will add a new shot size before the shot