INSTALLATION & START-UP INSTRUCTIONS 

Prosoft Elite Metered WATER 

SOFTENER 

 

Thank you for your purchase of a new Prosoft Elite 
Metered water softener from Quality Water Treatment! 
We have put together these instructions as a reference, 
and they are to be used as a general installation 
guideline.  

 

 
 

Pre-Installation Guide

 

 
Before you assembly your new system, be sure that the 
following conditions have been met for placement of your 

system: 
 

 

Level, firm surface, such as concrete, on which to place the 

softener tank and salt tank AKA Brine Tank  
 

 

Nearby floor drain or standpipe to connect to the softener for use during each 

regeneration  
 

 

Standard US plug, 120v 60hz (the softener system includes a 5ft. power cord and plug. Be 

sure the plug is not connected to a light switch 

 
Make a list of all the plumbing fittings to completely install the unit  
Typical is:  

 

 

Two - 3/4" or 1” male adaptors  

 

 

Eight - 90

°

 elbows  

 

 

Amount of pipe you need  

 

 

1/2" drain line and 90

°

 elbows  

 
Adding the Resin to the Water Softener Tank  

1. Position your new softener unit where you want it placed for use.  

 

2. Inside the Softener tank you’ll find a 3/4" or 1" gray or white Pvc tube (called a 

distributor tube.) If the tube does not already have a cap on the top use a pvc slip cap or 

some duct tape to temporarily plug this tube (this is to keep the resin from going down the 
tube.) If your system came with gravel, add the gravel first, then the resin. Use the included 
special funnel when adding the resin. This will take about 10 minutes. 

Summary of Contents for Prosoft Elite

Page 1: ...the softener for use during each regeneration Standard US plug 120v 60hz the softener system includes a 5ft power cord and plug Be sure the plug is not connected to a light switch Make a list of all the plumbing fittings to completely install the unit Typical is Two 3 4 or 1 male adaptors Eight 90 elbows Amount of pipe you need 1 2 drain line and 90 elbows Adding the Resin to the Water Softener Ta...

Page 2: ...alve hole Note no silicone or tape is needed the valve is o ring fit and only needs to be tightened by hand MediaGuard KDF Filter Installation Guide After adding the resin remove the temporary cap clean the valve threads with water attach mediaguard filter to bottom of control valve then screw the control valve on to the tank as the mediaguard filter slides over the distributor tube inside the tan...

Page 3: ...luding all outside faucets in order to drain the lines Unscrewing the aerator screen from your kitchen and bathroom faucets will help drain the lines faster 3 Cut and remove a 4 section of the water line where the unit is to be installed 4 Remove the two stainless steel clamps that are connected between the stainless steel bypass valve and the plastic meter assembly there is one clamp on each side...

Page 4: ...ipe you need to plumb the main hard water line into your softener unit Then do the same for the soft water line that will exit from the softening unit back out into the house 9 NOTE The unit will be marked either on the back of the valve body itself with the word IN and OUT or the top of the body of the bypass valve assembly with arrows showing the direction of water flow into and out of the valve...

Page 5: ... 5 feet over and above where it comes out of the valve and you can run it up to 100 feet away Always follow local codes Slide a 1 2 hose clamp over drain line and then slide drain line over drain hose barb Slide hose clamp over barb and tube and tighten the hose clamp Plug your power cord into a nearby outlet Assembly of Brine tank The float assembly is a safety float it only functions if there s ...

Page 6: ...n the brine tank and into the brine well Slip the plastic nut and the two ferules one black and one white over brine tubing then push brass insert and screen into brine tubing as shown in photo below Insert tube into top fitting on float shown in photo below and hand tighten then snug it up with a small wrench Note no tape is required this is a compression fitting Take the other end of tube slide ...

Page 7: ...st results may indicate GPG PPM or Mg L It is important to note that PPM and Mg L are the same measure and both figures can be treated interchangeably If you get a hardness figure in PPM or Mg L please divide this number by 17 1 to get Grains Per Gallon GPG Iron results should also be measured in either PPM or Mg L Add your level of iron multiplied by 3 Add this number to your hardness level This ...

Page 8: ... 56xt 6700 Press the extra cycle button Regenerant Flow Down flow Press the extra cycle button Display format US Gallons Press the extra cycle button Unit Capacity Set it to the capacity that your system is Press the extra cycle button Water Hardness Program in your hardness level Press the extra Cycle button Capacity safety factor 00 Press the extra Cycle button Volume override 1000 g Press the e...

Page 9: ... minutes for your system on the chart below 24 000 Grain system 8 minutes 32 000 Grain system 10 minutes 40 000 Grain system 11 minutes 48 000 Grain system 14 minutes 64 000 Grain system 16 minutes 80 000 Grain system 18 minutes 96 000 Grain system 20 minutes 110 000 Grain system 22 minutes Press the extra cycle button through the rest of the settings nothing needs to be changed Your system is pro...