26

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

950

115

47

1,245

230

48

1,045

149

1,280

258

1,440

354

0.2

895

124

50

1,195

238

50

990

160

1,225

259

1,390

365

0.3

840

134

54

1,150

247

52

935

167

1,180

274

1,355

369

0.4

775

146

58

1,095

256

55

875

179

1,130

280

1,300

383

0.5

710

152

63

1,045

263

57

820

186

1,085

293

1,260

396

0.6

650

160

X

990

277

61

755

194

1,030

295

1,210

402

0.7

590

163

X

935

285

64

700

197

975

304

1,160

397

0.8

540

171

X

870

288

X

650

214

920

315

1,110

415

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

1,100

172

51

1,420

325

53

1,075

162

1,335

274

1,620

484

0.2

1,040

181

54

1,360

331

55

1,015

172

1,290

288

1,575

489

0.3

985

185

57

1,310

342

57

960

185

1,230

297

1,530

497

0.4

920

193

61

1,275

353

59

900

188

1,185

304

1,490

500

0.5

875

203

64

1,210

360

62

845

200

1,130

321

1,450

507

0.6

815

207

X

1,165

368

64

790

208

1,075

321

1,405

518

0.7

765

215

X

1,115

369

X

740

211

1,030

325

1,345

516

0.8

710

216

X

1,075

385

X

680

217

980

330

1,300

528

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

1,085

171

52

1,410

326

53

1,225

227

1,475

367

1,790

641

0.2

1,035

178

54

1,365

329

55

1,190

240

1,430

366

1,745

650

0.3

985

184

57

1,315

337

57

1,120

246

1,375

378

1,710

659

0.4

925

193

61

1,270

353

59

1,070

254

1,320

383

1,670

663

0.5

870

198

65

1,220

360

61

1,015

266

1,270

397

1,625

674

0.6

815

208

X

1,175

372

64

970

265

1,230

400

1,585

672

0.7

760

213

X

1,115

375

X

920

279

1,185

409

1,540

675

0.8

710

219

X

1,080

381

X

875

280

1,140

417

1,495

683

GPG1636080M41**  -  Rise Range: 35° - 65°

E.S.P.

T1 LOW STAGE HEATING 

SPEED

T2 HIGH STAGE HEATING 

SPEED

T3 LOW STAGE 

COOLING SPEED

T4 HIGH STAGE 

COOLING SPEED

T5 COOLING SPEED

GPG1642100M41**  -  Rise Range: 35° - 65°

E.S.P.

T1 LOW STAGE HEATING 

SPEED

T2 HIGH STAGE HEATING 

SPEED

T3 LOW STAGE 

COOLING SPEED

T4 HIGH STAGE 

COOLING SPEED

T5 COOLING SPEED

GPG1648100M41**  -  Rise Range: 35° - 65°

E.S.P.

T1 LOW STAGE HEATING 

SPEED

T2 HIGH STAGE HEATING 

SPEED

T3 LOW STAGE 

COOLING SPEED

T4 HIGH STAGE 

COOLING SPEED

T5 COOLING SPEED

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

625

53

54

855

107

53

625

51

850

104

1,090

197

0.2

585

61

58

815

114

55

590

60

810

116

1,055

201

0.3

550

70

61

785

125

57

555

68

775

122

1,020

207

0.4

495

78

X

750

135

60

505

79

735

129

995

212

0.5

445

85

X

705

141

64

450

86

705

136

955

230

0.6

400

93

X

660

149

X

410

93

655

147

915

240

0.7

345

99

X

615

157

X

330

101

600

154

880

255

0.8

----

----

----

570

166

X

----

----

565

160

835

246

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

1,035

156

43

1,300

287

46

945

130

1,095

185

1,295

289

0.2

990

165

45

1,265

293

47

905

136

1,055

195

1,260

294

0.3

950

173

47

1,220

310

49

865

143

1,020

202

1,220

304

0.4

910

184

49

1,190

306

50

815

152

970

210

1,180

313

0.5

865

190

52

1,145

319

52

770

160

930

215

1,140

319

0.6

820

200

55

1,105

320

54

715

173

885

222

1,105

326

0.7

765

204

59

1,070

330

56

660

173

840

233

1,055

334

0.8

725

211

62

1,015

338

59

610

183

785

234

1,015

337

GPG1624060M41**  -  Rise Range: 35° - 65°

E.S.P.

T1 LOW STAGE HEATING 

SPEED

T2 HIGH STAGE HEATING 

SPEED

T3 LOW STAGE 

COOLING SPEED

T4 HIGH STAGE 

COOLING SPEED

T5 COOLING SPEED

GPG1630080M41**  -  Rise Range: 35° - 65°

E.S.P.

T1 LOW STAGE HEATING 

SPEED

T2 HIGH STAGE HEATING 

SPEED

T3 LOW STAGE 

COOLING SPEED

T4 HIGH STAGE 

COOLING SPEED

T5 COOLING SPEED

X = Outside of Temperature Rise Range  Not Recommended.

NOTE:

 

The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For 

satisfactory operation, external static pressure should not exceed 0.8" w.c.

BLOWER PERFORMANCE DATA

Содержание GPG 16 M Series

Страница 1: ...e and air flow may reduce energy efficiency and shorten equipment life ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL ADJUST SERVICE OR REPAIR HEREINAFTER SERVICE THE EQUIPMENT SPECIFIED IN THIS MAN...

Страница 2: ...Primary Limit 18 Flame Detected with Gas Valve Closed 18 Low Flame Signal 19 Abnormal Operation Cooling 19 Short Cycle Compressor Delay 19 High Pressure Switch Loss of Charge Switch 19 MAINTENANCE 19...

Страница 3: ...RNINGS EXACTLY COULD RESULT IN SERIOUS INJURY DEATH OR PROPERTY DAMAGE NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME USE COMMERCIALLY AVAILABLE SOAP SOLUTION MADE SPECIFICALLY FOR THE DETECTION OF LEAKS...

Страница 4: ...nt pas suivies pour chacun des appareils raccord s au syst me de ventilation au moment de sa mise en marche cela peut entra ner une intoxication au monoxyde de carbone ou la mort Les tapes suivantes d...

Страница 5: ...dition of the National Fuel Gas Code NFPA 54 ANSI Z223 1 and National Standard of Canada CAN CSA B149 Installation Codes The heating and cooling capacities of the unit should be greater than or equal...

Страница 6: ...e for fire protection proper operation and service access see appendix These clearances must be permanently maintained The combustion air inlet and flue outlet hoods on the unit must never be obstruct...

Страница 7: ...at the altitudes shown on the rating plate The rating plate is stamped with the model number type of gas and gas input rating Make sure the unit is equipped to operate on the type of gas available Con...

Страница 8: ...drip leg to trap dirt and moisture before it can enter the gas valve The drip leg must be a minimum of three inches long 5 Use two pipe wrenches when making connection to the gas valve to keep it from...

Страница 9: ...peration Because of the danger of ex plosion or fire never use a match or open flame to test for leaks Never exceed specified pressure for testing Higher pressure may damage gas valve and cause overfi...

Страница 10: ...nd two stages of me chanical cooling Units which will have economizers may use thermostats with two or three stages of cooling All units can use single stage or multi stage thermostats Refer to figure...

Страница 11: ...esidential or Manual Q Commercial All ductwork exposed to the outdoors must include a weather proof barrier and adequate insulation A duct system should be installed in accordance with Stan dards of t...

Страница 12: ...elay time expires the control will transition from low stage to high stage 6 The 30 second HEAT FAN ON delay time begins after the main burners light 7 The unit delivers heat to the conditioned space...

Страница 13: ...ated temperatures at the control are normally caused by blower failure The reason for the opening should be determined and repaired prior to resetting If the power to the unit is interrupted during th...

Страница 14: ...ternately remove pre drilled cap from drip leg Reinstall original cap sealing with pipe thread compound 7 Turn on electrical power and gas supply to the system 8 Turn on system power and energize valv...

Страница 15: ...e Rise Check Check the temperature rise through the unit by placing ther mometers in supply and return air registers as close to the unit as possible Thermometers must not be able to sample temperatur...

Страница 16: ...lower will continue to run for 90 120 150 or 180 seconds depending on the setting NOTE If necessary adjust fan OFF delay settings to obtain satisfactory comfort level Control Board Top Unit Shutdown 1...

Страница 17: ...3 Record the gauge pressure and the temperature of the line 4 The difference between the thermometer reading and pressure to temperature conversion is the amount of subcooling Subcooling Formula Sat...

Страница 18: ...d heat exchanger a failed induced draft blower or insufficient combustion air The rollout protection device is a manual reset limit located on the burner bracket The cause of the flame rollout must be...

Страница 19: ...ecked at least once a year before the heating season begins to be sure that the combustion air inlet and flue outlet hoods are not blocked by debris which would prevent adequate combus tion air and a...

Страница 20: ...r lifting off At least once a year prior to or during the heating season make a visual check of the burner flames NOTE This will involve removing and reinstalling the heat exchanger door on the unit w...

Страница 21: ...Switch Compressor Igniter Condenser Coil Ignition Control Condenser Fan Blade Induced Draft Blower Condenser Fan Motor Pressure Switch Contactor Pressure Switch Hose Gas Manifold Thermostatic Expansio...

Страница 22: ...Flashes Indoor Outdoor Thermostat Open Cooling Only Devices Not present On All Models 9 Flashes High Pressure Loss of Charge Switch Open Cooling Only Devices Not Present On All Models Amber Light Sig...

Страница 23: ...e Height W D A B GPG1624 M41 47 51 32 34 1 2 Medium GPG1630 M41 47 51 32 34 1 2 Medium GPG1636 M41 47 51 40 42 1 2 Large GPG1642 M41 47 51 40 42 1 2 Large GPG1648 M41 47 51 40 42 1 2 Large GPG1660 M41...

Страница 24: ...ECK FOR SHORTS IN FLAME SENSOR WIRING CHECK GAS VALVE CHECK ROLLOUT LIMIT SW CHECK AUXILIARY LIMIT SW CHECK MAIN LIMIT SWITCH C CHECK WIRING FOR SHORTS CHECK PRESSURE SWITCH PRESSURE SWITCH CLOSED CHE...

Страница 25: ...nufacturer s instal lation instructions D gaugement conforme aux codes d installation locaux aux exigences du fournisseur de gaz et aux instructions d instal lation du fabricant MINIMUM CLEARANCES UNI...

Страница 26: ...SPEED T5 COOLING SPEED GPG1642100M41 Rise Range 35 65 E S P T1 LOW STAGE HEATING SPEED T2 HIGH STAGE HEATING SPEED T3 LOW STAGE COOLING SPEED T4 HIGH STAGE COOLING SPEED T5 COOLING SPEED GPG1648100M41...

Страница 27: ...available on the web site in Partner Link Service Toolkit NOTE Ensure coils are rinsed well after use of any chemical cleaners Annual Inspection Qualified Servicer Only Your package unit should be ins...

Страница 28: ...ignment per installa on instructions Check refrigerant piping for rubbing and leaks Repair if necessary Check unit wiring to ensure i s no n contact with refrigerant piping or sharp metal edges Check...