Chapter 6 — Service and Repair
©2007 Global VR, Inc.
040-0168-01 Rev. B 3/14/2008
Page 39 of 64
Ground wires from system components must be securely connected to the ground lug on the
power plate, as shown in Figure 26. Components must not be grounded to the power plate
mounting bolts.
The Ethernet port on the power plate should be connected to the System Computer Ethernet port
to be ready for use by future software revisions.
Figure 26.
AC Power Plate
AC Power Strip Replacement
The AC power strip provides power to all of the components in the cabinet. Perform the
following steps to replace the power strip:
SHOCK HAZARD. Disconnect the AC power cord before performing
the following procedure.
1.
Turn the cabinet
OFF
.
2.
Disconnect the Cabinet AC Power Cord.
3.
Remove the rear door from the cabinet.
4.
Disconnect all components from the power strip.
5.
Disconnect the power strip Neutral and Line wires from the power transformer.
6.
Disconnect the power strip Ground wire from the AC Power Plate ground lug.
7.
Remove the power strip; it is held in place with Velcro
®
.
8.
Replace the power strip with an appropriate unit from GLOBAL VR
®
. Do not use a different
power strip. Be sure to connect each wire to the correct terminal. (See
Figure 35
on page 58.)
Be sure to connect each wire to the correct terminal. The ground wire
must be securely connected to the ground lug on the power plate or
the game will not function properly.