Parameter 21
– SELECTING “REQUESTED POSITIONING DISPLAY” OPTION
This parameter allows to enable/disable the displaying of the required position instead of
the real position, at the end of a positioning within the tolerance range.
Note: the parameter setting will be applied on both axes.
Example of selection: disabling
y E S
Press
to select the parameter
(see PARAM. SELECTION)
P 21
y E S
*
Press
to confirm the selection and
enter its settings
P 21
n o
*
Press
to choose the desired selection
P 21
n o
Press
to confirm and go back to
parameters selection
P 21
5 0.0
Press
to quit configuration and go back
to the positions display
2 0 0.0
Parameter 22
– SETTING OF SLOW MOVEMENT ± 10 V OUTPUT PERCENTAGE
With this parameter it is possible to set the percentage value to be applied on the ± 10 V
output (optional) for the axis movement at low speed. The value is applied both in positive
and negative direction.
Example of value setting X axis = 30% Y axis = 30%
5 0
Press
to select the parameter
(see PARAM. SELECTION)
5 0 P 22
5 0
Press
and
to select both axes
5 0 P 22
0 0 0 0 0 0
*
Press
to confirm the selection and
enter the X axis setting
5 0 P 22
Содержание THESI 320
Страница 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Страница 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Страница 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Страница 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...