When switched on, the position controller sets itself for manual operation and only the axis
displays turn on.
In this operating mode, the axis movement can be controlled with the following keys:
or
TO SELECT THE AXIS TO BE MOVED
SLOW FEED AXIS MOVEMENT
SLOW BACK AXIS MOVEMENT
FAST FEED AXIS MOVEMENT
FAST BACK AXIS MOVEMENT
TO DESELECT THE AXIS
Note:
If, during movement, the programmed minimum or maximum measuring length limits are
overcome, the axis stops and the led of the START key begins to flash. This indicates the
overcoming of limits due to low or high speed inertia.
Press the STOP key to cancel the signaling.