USER MANUAL
POSITION CONTROLLER THESI 320
MT02_A41_A_TH320_GIVI_ENG rev. E
Pag. 19/60
Parameter 06
– AXIS RESOLUTION
This parameter allows to select the axis resolution, based on the number of pulses of the
encoder (PPR).
The resolutions that can be set are: 200 – 100 – 50 – 20 – 10 – 5 – 2 – 1 µm
or: 0.01 – 0.005 – 0.002 – 0.001 – 0.0005 – 0.0002 – 0.0001 – 0.00005 inch
Example: selecting 10 µm on X and Y axes
0.1
Press
to select the parameter
(see PARAM. SELECTION)
0.1 P 06
0.1
Press
and
to select both axes
0.1 P 06
0.1
*
Press
to confirm the selection and
enter the X axis setting
0.1 P 06
0.0 1
*
Press
to select the desired encoder
resolution
0.1 P 06
0.0 1
Press
to confirm the value and
enter the Y axis setting
0.1
*
P 06
0.0 1
Press
to select the desired encoder
resolution
0.0 1
*
P 06
0.0 1
Press
to confirm the value and go back
to parameters selection
0.0 1 P 06
5 0.0
Press
to quit configuration and go back
to the positions display
2 0 0.0
Parameter 07
– SETTING OF MINIMUM MEASURING LENGTH LIMIT
With this parameter, it is possible to set the positions of the minimum measuring length
limits, beyond which the machine will not execute movements.
Содержание THESI 320
Страница 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Страница 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Страница 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Страница 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...