USER MANUAL
POSITION CONTROLLER THESI 320
MT02_A41_A_TH320_GIVI_ENG rev. E
Pag. 53/60
SLOW / FAST
The SLOW / FAST outputs are used to control the axes movements in the two speeds, in
any of the operating modes: manual/semi-automatic/automatic. The outputs correspond to
N.O. relay contacts connected to their common COM FS; they alternatively close to
command the axis movement and they open to terminate the movement.
± 10 V ANALOG OUTPUT
The 0 V and AV analog output is used to control axes movements in positive (0 / +10 V) or
negative (0 / -10 V) direction, in the two speeds (see parameters 22 and 23), in any of the
operating modes: manual/semi-automatic/automatic.
The analog output is optional and alternative to the direction and speed relay outputs.
AUX X / Y
An AUX output, used for special applications, is available for each axis.
The status (ON/OFF) of these outputs can be programmed during the memorization of a
program. When this will be executed, during the various program cycles, the outputs will
assume the previously programmed status.
The output corresponds to a N.O. contact.
MAN-SEM / AUT
The M-S/A output corresponds to a N.O. contact in manual and semi-automatic operation,
and it closes in automatic mode.
END PROGRAM
The END PROG output corresponds to a N.O. contact that closes for around 0.5 seconds,
at the end of a program execution in automatic mode.
AUX
The AUX output is used for special applications.
This output corresponds to a N.O. contact.
Содержание THESI 320
Страница 1: ...User Manual Position Controller T TH HE ES SI I 3 32 20 0 www givimisure it...
Страница 57: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 57 60 NOTES...
Страница 58: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 58 60 NOTES...
Страница 59: ...USER MANUAL POSITION CONTROLLER THESI 320 MT02_A41_A_TH320_GIVI_ENG rev E Pag 59 60 NOTES...