MDE-4318D Competitive Pump and CRIND (CPC) Hardware/Software Start-up and Service Manual · May 2010
Page 3
Model Number Breakdown
Passport CPC Overview
Model Number Breakdown
Model Number PA0338ABCD
Refer to the table below for details of the convention used for the last four digits of the model
number.
Digit
Description
Possible Value
Denotes
A
Voltage
0
115 VAC
1
230 VAC
B
Reserved
-
-
C
Reserved
-
-
D
Dispenser Interface
0
Wayne
1
Tokheim
For proper operation, it is critical that all electrical wiring (for both the dispensers/CATs and POS
system) conform to National Electrical Code (NEC), NFPA 30A, and local wiring codes. On new
installations, ensure that all wiring meets specifications. For existing locations, it is important that
existing electrical wiring is inspected and approved before installing the Passport POS system
equipment.
Ensure the following when you install a Passport system for use with CPC:
• One conduit from the breaker panel to the D-Box is required. The conduit must contain a
dedicated/isolated circuit with three 14 AWG wires: 115 VAC hot, neutral and ground or 230 VAC
L1, L2, and ground. Do not use the same electrical conduit to provide an earth ground.
• An AC outlet must be located within 6 feet of the D-Box. Do not use extension cords to obtain a
power source for the D-Box.
• The circuit powering the D-Box must not power other devices. The circuit must not share a conduit
with wiring for other devices that draw high amperage (for example, compressor, freezer, and so
on) or devices that are sources of Radio Frequency Interference (for example, TV, microwave,
intercom, and so on).
• All non-Gilbarco devices and dispensers must be on the same phase as the Gilbarco Passport
system.
• Wiring for variable speed STPs cannot occupy the same space as communication wires (either in
conduit or within a wiring trough).
• Data wires cannot be shared between CATs or dispensers (daisy-chaining at the forecourt, wiring
trough, or D-Box is not allowed).
• Any concerns found with electrical wiring must be addressed before installing the Passport
system. Refer to FE-346 Field Wiring Diagram - Wayne CPC for additional wiring and installation
considerations.
IMPORTANT INFORMATION