MDE-4318D Competitive Pump and CRIND (CPC) Hardware/Software Start-up and Service Manual · May 2010
Page 7
Forecourt Configuration
Passport CPC Overview
To program the forecourt, proceed as follows:
Dispensers Tab
1
On the Dispensers tab, highlight the required fueling position and click
Change
.
Figure 1-2: Forecourt Installation Screen (Dispensers Tab)
Note: Screen shown as an example only.
2
Enter or select data for the following fields:
•
Manufacturer
: Enter the manufacturer’s name.
•
Pump Protocol
: Select the communication protocol for the fueling position.
Note: Supported protocols are Gilbarco, Wayne, and Tokheim. These protocols may be
mixed. However, the devices must be on separate loops.
•
Model
: Enter the model number.
•
Serial Number
: Enter the serial number.
•
Pay at Pump
: Select the checkbox if a CRIND/CAT is associated with the pump.
•
Type
: Select the type of fueling unit from the drop-down list.
•
Address
(Loop)
: Enter the number of the pump loop that is used by this fueling unit to
communicate.
•
Address
(Device ID)
: Enter a fueling position number between 1–24 in this field.
Note: This is the physical address of the position as programmed within the dispenser
electronics. This address may not always be identical to the number assigned by the
Passport system in the “No.” column.