Reference Information
Page 80
MDE-3985L Encore® Installation Manual · May 2006
Field Wiring through Side Column
Standard Encore units are not shipped with junction box. All electrical runs for Encore units
are to be provided at the site by the installer unless a junction box is ordered for the unit.
Conduit may be routed through the dispenser pit box or external to the pit box through the side
column.
Note: Gilbarco does supply junction box kits. For information on how to order a Junction
Box, contact a Gilbarco Customer Service Representative at 1-800-800-7498 (US and
Canada). For additional information on Junction Box kits, refer to MDE-4084 Junction
Box Retrofit Kit M01483K006 Installation Manual.
The instructions given below are for adapting conduit rising from the right of the pit box when
facing side 1. The process on the left is similar in concept.
Field wiring through the side column location can be installed as follows:
Note: these instructions are for units without pre-installed junction boxes.
1
On the lower right corner of the frame end, locate the rectangular opening. See
Figure 4-7
.
Figure 4-7: Encore Frame Assembly with Conduit
Note: Each end has an opening which is diagonally opposite of another opening. The opening
can be used to pass electrical conduit from the narrow space inside the column through
the frame opening. The conduit is finally run through the air gap plates into the
electronic module in the location shown in
Figure 4-7
.
All standard safety precautions for hazardous locations are to be taken and maintained
while this work is being performed.
Do not use electrically powered (battery or corded) tools in the work area.
Do not smoke or allow open flames in work area.
Always remember to power down all circuits before performing work.
Failure to following these precautions
may
result in serious injury or death.
WARNING
Opening for
1 conduit
(center location)
Rectangular
opening
(lower left)
Rectangular
opening
(lower right)
Y sealing
conduit
Air gap plate
1
''
NPT
(tapered
threads)
Stub up location for main
power and two wires
Side
1
Side
2
Содержание Encore 300 Series
Страница 1: ...Encore Installation Manual MDE 3985L...
Страница 58: ......
Страница 65: ...Dimensions are in inches...