![GILBARCO VEEDER-ROOT Encore 300 Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/gilbarco-veeder-root/encore-300-series/encore-300-series_installation-manual_2227130026.webp)
Installation
Page 22
MDE-3985L Encore® Installation Manual · May 2006
Pumps (MPD) Configurations
For pump blenders go to
Pump Blender Configurations on page 26.
Figure 3-7: Encore Pump (MPD) Product Inlets and J-Box
Model #
Multi Product Pump
Model Description
Encore
Inlets
Product Inlets
(Typical)
NC0
1 Grade 2 Hose MPD Pump
W
W = Product 1
NC1
2 Grade 4 Hose MPD Pump
W,X
W = Product 1
X = Product 2
NG5
2 Grade Single Hose MPD Pump
NC2
3 Grade 6 Hose MPD Pump
W,X,Y
W = Product 1
X = Product 2
Y = Product 3
NG2
Single Hose MPD Pump 3 Grade 2 Hoses
NC3
MPD Pump 4 Grade 8 Hose
W,X,Y,Z
W = Product 1
X = Product 2
Y = Product 3
Z = Product 4
NG3
Single Hose +1 MPD Pump, 3+1 Grade, 4 Hoses
W,X,Y,+Z
W = Product 1
X = Product 2
Y = Product 3
+Z = Straight/
Unblended Product
Notes:
Table information assumes two-sided units.
1. Z is always a Straight/Unblended Product Inlet; +Z is always a Straight/Unb1
Product.
2. Product number does not signify grade on MPD units, for example; Product 1 is not
always Lo Grade, but is optionally Lo, Mid or Hi.
The FCC/Patent plate is on the inner sheathing to the right when facing side 1
Z
Y
X
W
J-box
Main conduit