Installation
Figure 3-31: Hanging Hardware
4
Install swivel, if used, to hose. Follow swivel manufacturer instructions.
5
Install nozzle to swivel or hose. Follow nozzle manufacturer instructions.
Note: Check for correct nozzle cradle/hook type (vapor, non-vapor, and so on). It must not be
possible to activate the nozzle boot switch with the nozzle properly held in place in the
nozzle boot.
6
Using an ohm meter, check for continuity from end of nozzle to conductive metal surface in
unit. (Applies to both types of hoses - retrievers or non-retrieving.)
Units With Hose Retrievers or Extended Reach
Note: It is important that teflon tape not be used on threaded connections. Use UL approved
sealant suitable for the fuel involved only where required for sealing. (Not used for O
rings.)
1
Attach swivel (if used) to nozzle. (Follow swivel manufactures instructions.)
2
Assemble and attach breakaway whip hose to swivel or nozzle. (Follow hose manufacturers
Instructions.)
3
Assemble breakaway to whip hose. Follow breakaway manufacture instructions.
breakaway
nozzle
swivel
hose
whip hose
WARNING
Hose fittings and attachments, if improperly grounded, can lead to a spark that may ignite fuel
or its vapors.
Explosion or fire could result in severe injury or death.
Check hoses, breakaways, fittings for proper conductivity after assembly.