Reference Information
Page 74
MDE-3985L Encore® Installation Manual · May 2006
Twisted-Pair Conduit
Gilbarco recommends use of 1-inch rigid conduit and fittings (See
Conduit on page 71)
for
twisted-pair cable(s).
This will allow up to two speakers and two call/stop buttons per side,
plus ethernet.
Note:
T
erminate conduit in dispenser containment pan consistent with all national and local
electrical codes.
Twisted-Pair Cable
Gilbarco requires use of only 10Base-T cable as specified in this document. Gilbarco specified
cable
must
be used to permit issuance of a Certificate of Conformance and/or warranty. Use of
other type cables may also create a hazardous situation.
Cable Ordering Information:
Twisted-Pair Installation Personnel and Procedures
Twisted-pair wiring must be installed by certified telecommunications technicians in
accordance with ANSI/TIA/EIA 568-A Commercial Building Telecommunication Cabling
Standards (and Amendments). Installing technician must read and understand the following:
Type
Comments
Q13221-02
Wire - 600 Volt Stranded, Annealed Copper Tinned with PVC Insulation
Type TFFN or
NTW
UL Approved Gasoline and Oil Resistant
18 AWG
Wire with 10-12 twists per foot
Document
Title
ANSI/IEEE 142-1991
Recommended Practice for Grounding of Industrial and Commercial Power Systems
(IEEE Green Book)
ANSI/IEEE 1100
Recommended Practice for Powering and Grounding Sensitive Electronic
Equipment (IEEE Emerald Book)
ANSI/TIA/EIATSB67
Transmission Performance Specification for Field Testing of Unshielded Twisted-
Pair Cabling Systems
ANSI/TIA/EIA568-A
Commercial Building Telecommunication Cabling Standards (with amendments)
Petroleum vapors may migrate inside cable insulation between conductors and
sheathing of various cables, including 10Base-T cable. Vapors may ignite, leading to
serious injury or death.
Use only twisted-pair cable specified by Gilbarco.
Cable has these properties: Safety Certification: UL Listing AWM Style 21094 80
degrees C 300 volts. Vapor Test: Compliant to UL Standard 87, Section 36A, Para. 22.17
DANGER
!
A copy of the ANSI/TIA/EIA TSB 67 certification of conformance from the wiring personnel must
be provided to the ASC before the site can be commissioned. The certificate is part of the
documentation that must be on file at the installation site. A certification of the field test will be
required at equipment start-up. Contact Gilbarco with any questions regarding this procedure.
IMPORTANT NOTICE
Содержание Encore 300 Series
Страница 1: ...Encore Installation Manual MDE 3985L...
Страница 58: ......
Страница 65: ...Dimensions are in inches...