Installation
Page 48
MDE-3985L Encore® Installation Manual · May 2006
4
Assemble hose to breakaway and then to unit outlet casting. Follow breakaway manufacture.
instructions.
5
Attach retriever clamp to long hose positioned to allow maximum extension of the hose yet
not allow a trip hazard.
Do Not Turn on AC Power!
When all installation procedures are complete to this point, the system must be purged by the
installing contractor with a Gilbarco ASC on site to apply power needed to perform this
procedure. Refer to MDE-3804 Encore and Eclipse Service/Start-Up Manual for start-up
instructions. Whether purging is performed now or later, proceed to and complete section
Installation Checklists on page 50
.
Purging Air from System
For New Dispensers (Purging through shear valve)
Encore dispensers must have some programming changes completed before purging can be
started.
Encore 500/500 S
Encore 500/500 S units are received un-calibrated. Purging requires the unit to be configured
for gallons, liters or imperial gallons. When purging, follow the calibration procedure in
Purging Encore 300 Special Procedure on page 49
.
WARNING
Hose breakaways may not operate properly during a drive off if the retriever clamp is located
between the breakaway and the pump dispenser.
The unit may be pulled off an island during a drive off or fuel may be spilled resulting in a serious
injury to death.
Do not install the hose retriever clamp between the nozzle and breakaway.
WARNING
Applying power before electrical and mechanical inspections have been completed
can be hazardous. Hazardous high voltage, fuel and fuel vapors may be present or
equipment may be damaged.
Serious fires, explosions, electrical shocks, and injuries or deaths could result.
Power must not be applied to unit and associated STPs when installing, servicing or
making electrical wiring connections or replacing any electrical components, including
light bulbs. Multiple disconnects may be required.
Only a Gilbarco Authorized Service Contractor may apply power during or after
installation to check for leaks, verify operation, assure sealing of all enclosures,
replacement of all covers, skins and sheathing and commission unit for operation per
Installation Checklists on page 12
prior to applying power. Failure to comply with this
mandate could additionally result in loss of unit warranty.