Reference Information
Page 72
MDE-3985L Encore® Installation Manual · May 2006
Data Wire Lengths
Use the following table to determine maximum data wire lengths.
Note: When installing new 2-Wire Communication wiring, use unshielded twisted-pair data
wires. Do not use shielded wire. Wiring spec: 2-wire twisted-pair (UTP) with 10 to 12
twists per foot, stranded annealed copper tinned with 18 AWG minimum required for
runs up to 1000 feet or 14 AWG minimum for runs up to 2600 feet. Do not daisy chain
communications wiring. Insulation spec: PVC insulation of type TFFN or MTW, UL
approved gasoline and oil resistant. Reference C&M Corporation Part #27525 (18
AWG) or equivalent. Gilbarco part number for wire is: Q13221-02.
For this Distribution Box
The Distance Between the
Distribution Box and Dispenser
The Distance Between the
Distribution Box and
Console/Controller
PA0133, PA0187 G-SITE
®
Total data wire system run no more than 2600 ft. with 14 AWG.
PA0242 Transac System
1000
No more than 2600 ft. with
14AWG.
No more than 2600 ft. with
14AWG.
PA0261 Universal D-Box
No more than 2600 ft. with
14AWG.
No more than 2600 ft. with
14AWG.
PA0306 Distribution Box
No more than 2600 ft. with
14AWG.
No more than 2600 ft. with
14AWG.