Installation
Page 32
MDE-3985L Encore® Installation Manual · May 2006
Figure 3-16: Anchors for Pump/Dispenser
Connecting Vapor Return Line to Vapor Shear Valve
Do not create any liquid traps when connecting the vapor return line to the vapor line shear
valve. See
Figure 3-17
. A liquid trap is a low spot in the vapor return line that can accumulate
fuel and cause blockage which could cause a system to fail vapor recovery certification tests.
Note: Contractor must provide and install pipe union for connection to 1-inch NPT coupling
in unit.
Figure 3-17: Correct Vapor Line Connection Method
Contractor
supplied fittings,
for example;
anchor bolts
Correct
Do not allow liquid traps
No place for liquid
to be trapped
Not Allowed
1
''
NPT Vapor return pipe supplied in unit
Contractor supplied
fittings, pipe and
shear valve.
Contractor
supplied
fittings, pipe
and shear
valve.
Vapor line shear valve