61301604086
5–1
Section 5 Troubleshooting
PROBLEM
PROBABLE CAUSE
CORRECTION
No power or screen is blank.
1.
Building’s electrical supply
disconnect switch (circuit
breaker) is off.
2.
Primary breaker on
transformer tripped.
3.
Secondary breaker on
transformer tripped.
4.
GFI is tripped.
5.
Control board failed.
1.
Set the switch to the on
position.
2.
Reset circuit breaker
3.
Reset circuit breaker
4.
Check GFI.
5.
Replace the control board.
Machine is constantly draining.
1.
Control signal off.
2.
Drain valve is worn.
1.
Use meter to check signal.
2.
Rebuild or replace drain valve
as necessary.
Machine leaks water into cabinet
when it drains water.
1.
House water fill valves faulty.
2.
Jet valve is worn.
1.
Check house water fill valves
If valves work, but continue to
leak, replace valve seals.
If valves do not work, replace
valves.
2.
Rebuild or replace the jet
valve
Processor does not read door open
or sound alarm.
Door switch is damaged.
Replace the door switch.
Pump pressure is higher than
normal (30-40psi).
1.
Spray jets plugged.
2.
Self cleaning screen plugged
with debris.
1.
Flush out jets. See “CLEAN
THE SPRAY JETS AND
HEADERS” on page 4-4
2.
Clean screen. See “INSPECT
THE AUTOMATIC SELF-
CLEANING DEBRIS FILTER
SCREEN AND SUMP” on
page 4-3
Содержание Castle MTP 1800 Series
Страница 1: ...SERIES 1800 CAGE AND BOTTLE WASHER OPERATING MANUAL 61301604086 Rev A...
Страница 2: ......
Страница 68: ...Troubleshooting 5 6...
Страница 74: ...Installation Instructions 6 6...
Страница 92: ...Optional Equipment 7 18...