5 - 14
Genie Z-60/34
Part No. 75861
November 2003
Section 5 • Fault Codes
REV A
Code
Problem
Cause
Solution
FAULT CODES
531
TPS1 (Signal Voltage)
High
The #1 throttle position sensor
wiring and/or connections open
or shorted OR there is a poor
system ground connection OR
throttle position sensor #1 is
faulty.
Be sure system ground
connections are in place and
secure OR repair wiring
and/or connections to sensor
OR replace throttle position
sensor #1.
532
TPS1 (Signal Voltage)
Low
The #1 throttle position sensor
wiring and/or connections open
or shorted OR there is a poor
system ground connection OR
throttle position sensor #1 is
faulty.
Be sure system ground
connections are in place and
secure OR repair wiring
and/or connections to sensor
OR replace throttle position
sensor #1.
533
TPS2 (Signal Voltage)
High
The #2 throttle position sensor
wiring and/or connections open
or shorted OR there is a poor
system ground connection OR
throttle position sensor #2 is
faulty.
Be sure system ground
connections are in place and
secure OR repair wiring
and/or connections to sensor
OR replace throttle position
sensor #2.
534
TPS2 (Signal Voltage)
Low
The #2 throttle position sensor
wiring and/or connections open
or shorted OR there is a poor
system ground connection OR
throttle position sensor #2 is
faulty.
Be sure system ground
connections are in place and
secure OR repair wiring
and/or connections to sensor
OR replace throttle position
sensor #2.
535
TPS1 Higher than
TPS2
The throttle position sensor
wiring and/or connections for
either TPS1 or TPS2 open or
shorted OR there is a poor
system ground connection OR
one or both throttle position
sensors are faulty.
Be sure engine harness wiring
and connections are in place
and secure OR repair wiring
and/or connections to one or
both TPS sensors OR replace
one or both TPS sensors.
Содержание Z-60/34
Страница 1: ...Part No 75861 November 2003 Rev A Service Manual Refer to inside cover for serial number information ...
Страница 12: ...Genie Z 60 34 Part No 75861 November 2003 This page intentionally left blank ...
Страница 154: ...5 18 GenieZ 60 34 PartNo 75861 November 2003 Section 5 Fault Codes This page intentionally left blank ...
Страница 157: ......
Страница 160: ...Electrical Schematic Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Страница 162: ...Ground Control Box Wiring Diagram Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Страница 164: ...Platform Control Box Wiring Diagram Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Страница 165: ......
Страница 168: ...Electrical Schematic Ford LRG 425 EFI Models November 2003 Section 6 Schematics ...
Страница 170: ...Ground Control Box Wiring Diagram Ford LRG 425 EFI Models November 2003 Section 6 Schematics ...
Страница 172: ...Platform Control Box Wiring Diagram Ford LRG 425 EFI Models November 2003 Section 6 Schematics ...
Страница 173: ...November2003 Section 6 Schematics PartNo 75861 GenieZ 60 34 6 11 ...
Страница 176: ...Hydraulic Schematic 2WD Models before serial number 4461 November 2003 Section 6 Schematics ...
Страница 178: ...Hydraulic Schematic 4WD Models before serial number 4461 November 2003 Section 6 Schematics ...
Страница 180: ...Hydraulic Schematic 2WD Models after serial number 4460 November 2003 Section 6 Schematics ...
Страница 182: ...Hydraulic Schematic 4WD Models after serial number 4460 November 2003 Section 6 Schematics ...