8.5
Monitored Photocell Self-diagnostic Troubleshooting Chart
www.geniecompany.com
04-14
ON
ON
NORMAL OPERATION
NONE REQUIRED
OFF
OFF
1. POWER HEAD NOT POWERED
2. WIRING
FROM
POWER
HEAD
BAD
1. CHECK BREAKERS, FUSES, PLUGS
2. CHECK WIRING FOR OBVIOUS SHORTS
OFF
ON
1. WIRING TO SOURCE MISSING OR BAD
2. POWER HAS BEEN INTERRUPTED
1. CHECK WIRING
2. REMOVE POWER AND REAPPLY
2 BLINKS, PAUSE
(REPEAT)
ON
1. BEAM NOT ALIGNED
2. BEAM OBSTRUCTED
3. SENSOR DEFECTIVE
1.CHECK ALIGNMENT
2. CHECK FOR OBSTRUCTION
3. CALL CUSTOMER SERVICE
1. WIRE TO SENSOR MISSING OR BAD
2. SENSOR DEFECTIVE
1. CHECK WIRING
2. CALL CUSTOMER SERVICE
OFF
ON
1. SENSOR RECEIVING INTERFERENCE
ON
1. SOURCE NOT SENDING PULSES
2. SOURCE DEFECTIVE
1. CALL CUSTOMER SERVICE
2. CALL CUSTOMER SERVICE
SOURCE (RED LED) SENSOR (GREEN LED)
INDICATED CONDITION
REQUIRED ACTION
2 BLINKS, PAUSE
(REPEAT)
3 BLINKS, PAUSE
(REPEAT)
4 BLINKS, PAUSE
(REPEAT)
1. ATTEMPT TO DETERMINE SOURCE OF
INTERFERENCE
2. CALL CUSTOMER SERVICE
WARNING:
ACTUATING THE OPERATOR BY USING CONSTANT
CONTACT ON THE CLOSE BUTTON WILL OVERRIDE NON-FUNCTIONING EXTERNAL
REVERSING DEVICES, INCLUDING PHOTOCELLS.
AVERTISSEMENT:
L'ACTIVATION DE L'OPERATEUR
EN UTILISANT UN CONTACT CONSTANT SUR LE BOUTON FERMER ANNULERA LES
DISPOSITIFS D'INVERSIONS EXTERNES, Y COMPRIS LES CELLULES PHOTOELECTRIQUES.
WARNING:
The Genie® Company
recommends that line voltage wiring be performed by qualified
electrician. See Section 5 for additional wiring instructions.
AVERTISSEMENT:
Genie® Company
recommande que le câblage au secteur soit effectué
par un électricien qualifié. Voir la section 5 pour des instructions
supplémentaires sur le câblage.
Содержание GCL-J&H 1/2HP
Страница 2: ...THIS PAGE LEFT BLANK...
Страница 66: ...THIS PAGE LEFT BLANK...
Страница 67: ...THIS PAGE LEFT BLANK...
Страница 68: ...1 Door Drive Mt Hope Ohio 44660 www geniecompany com 1 1 1 8 4 5 5 0 2 3 5 1...