Some installation tasks listed in 

this document are found in other 

documents. 

Please refer to the appropriate 

document(s) as directed; 

308577 Hilti Kwik Bolt Installation 

found on Ribbon Connect

41510.00119 Installation 

Instructions for Motor Enclosure 

(Included)

This installation manual provides 

the trained door technician 

information required to install 

this door.

READ COMPLETE INSTRUCTIONS 

BEFORE INSTALLING DOOR.

This manual is intended ONLY 

for professional use by a trained 

door systems technician. All 

others please refer to the end 

user manual provided to you.

INSTALLATION INSTRUCTIONS 

MODEL 523RX RESIDENTIAL EXTERIOR SECURITY SHUTTER, 

WITH SIDE MOUNT MOTOR ENCLOSURE

After installation is complete, 

leave this manual with the 

Homeowner. Maintenance 

instructions on page 20.

Содержание 523RX

Страница 1: ...r Enclosure Included This installation manual provides the trained door technician information required to install this door READ COMPLETE INSTRUCTIONS BEFORE INSTALLING DOOR This manual is intended O...

Страница 2: ...67 0001 NEW 10 08 2020 TABLE OF CONTENTS SECTION CONTENTS PAGES 1 SAFETY INFORMATION 3 2 KEY DRAWING 4 3 DOOR INSTALLATION DATA SHEET 5 4 PRE INSTALLATION CHECK LIST 6 5 INSTALLATION 7 14 6 MOTOR WIRI...

Страница 3: ...and instructions OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION SECTION 1 SAFETY INFORMATION Upward Rolling Doors doors are large heavy objects that move with the help of electric motors S...

Страница 4: ...n of Overhead Door Corporation 4 500367 0001 NEW 10 08 2020 FIG 2 Please note that components and component locations are shown here for REFERENCE ONLY Your unit installation and component locations m...

Страница 5: ...ocate the work order Door Installation Data sheet inside the door hardware box You will need to refer to the Door Installation Data sheet See FIG 2 Factory order number on door components must match w...

Страница 6: ...the Opening Width and Height shown on the Door Installation Data sheet Are the guides you received suitable for the jambs Compare the guides type shown on the Door Installation Data sheet with FIG 4...

Страница 7: ...FIG 4 on page 5 G Dimension must match your DOOR INSTALLATION DATA sheet Both guides MUST be on a level line and both guides MUST be plumb The G Dimension must be held within 1 8 over the entire heigh...

Страница 8: ...t and lower it onto the top of the guides inserting the support bars into the guide as shown in FIG 6 Be sure the support bars are fully inserted into the guides on both sides See FIG 7 Install the wa...

Страница 9: ...fork lift or other appropriate lifting equipment and lower it attaching it to the back of the jamb as shown in FIG 8 Be sure the bottom of the fascia plate is approximately 4 1 2 below the top of the...

Страница 10: ...formed only by a trained door system technician using proper tools and instructions WARNING Rapidly closing curtain could result in death or serious injury Use caution when lowering curtain before spr...

Страница 11: ...sion of Overhead Door Corporation 11 500367 0001 NEW 10 08 2020 STEP 4 STEP 4 ATTACH BOTTOM BAR STOPPER SECTION 5 INSTALLATION With door in the closed position attach stopper using stud plate and nuts...

Страница 12: ...FRONT HOOD SECTION 5 INSTALLATION Position the hood in place as shown in FIG 13 Align the hood and attach using the screws and wall fasteners provided See FIG 13 and FIG 14 If your door is 12 0 or wi...

Страница 13: ...the shaft all the way through the coupler attached to jackshaft operator in the box See FIG 15 and FIG 16 Once the Motor Enclosure is in position and aligned mark the four locations onto the jamb See...

Страница 14: ...Copyright 2020 Wayne Dalton a division of Overhead Door Corporation 14 500367 0001 NEW 10 08 2020 SECTION 5 INSTALLATION STEP 6 STEP 6 INSTALL OPERATOR Continued FIG 16 FIG 17...

Страница 15: ...put power wiring must be properly sized for the operators amperage rating This motor requires 115V single phase 60Hz power WARNING WARNING To avoid serious injury or death DO NOT calibrate motor or op...

Страница 16: ...o the curtain guide as shown in FIG 18 IMPORTANT DO NOT REMOVE FACTORY INSTALLED INTERLOCK WIRE UNLESS INSTALLING AN INTERLOCK THIS JUMPER IS REQUIRED FOR PROPER OPENER OPERATION Wire the interlock sw...

Страница 17: ...MOTOR WIRING FIG 20 Install photo eyes onto the curtain guides as shown in FIG 20 Wire the photo eyes to the bottom of the Motor Enclosure using cable gland water tight connector and to the STB conne...

Страница 18: ...alton a division of Overhead Door Corporation 18 500367 0001 NEW 10 08 2020 STEP 9 STEP 9 ATTACH GUIDE COVERS SECTION 7 FINAL INSTALLATION FIG 22 Align guide covers on guides and snap into place See F...

Страница 19: ...Do NOT permit children to play on near or with door or to operate controls 5 Unlock door before opening door 6 Sensing devices on motor operated doors should be tested frequently 7 Adjustments or rep...

Страница 20: ...yne Dalton dealer for more details on their program offering Increase operational efficiency safety and reliability Extend useful life of your equipment Reduce probability of equipment malfunctioning...

Страница 21: ...resulting from scratching abrasion or impact by any hard object and any fading or color change which may not be uniform due to unequal exposure of the curtains to sunlight or other elements Wearing a...