background image

GDO-9v2 SecuraLift

®

INSTALLATION INSTRUCTIONS  |  OWNERS COPY

Overhead Garage Door Opener

Featuring

TrioCode

Technology

Part # 13212 (Manual)

Содержание GDO-9v2 Enduro Gen 2

Страница 1: ...GDO 9v2 SecuraLift INSTALLATION INSTRUCTIONS OWNERS COPY Overhead Garage Door Opener Featuring TrioCode Technology Part 13212 Manual ...

Страница 2: ...be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Automatic Technology Australia Pty Ltd Garage Door Opener Automatic Technology Australia Pty Ltd hereby further expressly excludes all or any liability for any injury damage cost expense or claim whatsoever suffered by any pe...

Страница 3: ... Transmitter 18 Safety Obstruction Forces 19 Safety Obstruction Force Test 19 Adjusting Safety Obstruction Forces 20 Coding Transmitters 21 Door 21 Courtesy Light 21 Pet Mode 21 Vacation Mode 21 Remotely Coding Transmitters 22 Erasing Transmitter Codes 22 Accessories 23 Photo Electric Beam Installation 23 Auto Close Setup 23 SmartSolar Installation 24 Battery Back Up installation 25 Final Set Up 2...

Страница 4: ...ilure to follow this warning DO NOT allow children to operate the SecuraLift Serious personal injury and or property damage can result from failure to follow this warning Regularly check to make sure that the safety obstruction force is working correctly and is tested and set as per page 19 of this manual Failure to follow these instructions could result in serious personal injury and or property ...

Страница 5: ...ower outlet installed by a qualified electrical contractor Disconnect the power cord from mains power before making any repairs or removing covers Only experienced service personnel should remove covers from the opener When using auto close mode a photo electric beam must be fitted correctly and tested for operation at regular intervals Extreme caution is recommended when using auto close mode All s...

Страница 6: ...rts such as cams and microswitches During installation the hand held transmitter can be programmed to set the door limits positions ISS intelligent safety obstruction system While the door is performing a close cycle should it hit an obstacle or be restricted in some manner it will automatically reverse The amount of force the door should encounter before reversing is automatically adjusted by the...

Страница 7: ...en the door to an adjustable partial height so that the family pet can enter and exit the garage at any time You may also wish to open the door to a height suitable only for pedestrian access Auto close mode The opener can be programmed to automatically close after an open cycle The auto close time is adjustable It is compulsory to install a P E Beam if this mode is selected otherwise the door may...

Страница 8: ...on red is used during installation to help set the close limit position Pressing and holding this button will move the door in the close direction Movement stops when the button is released NOTE The safety obstruction detection is inoperable when the CLOSE button is used to move door PLUS button green is used during installation to help set the open limit position Pressing and holding this button ...

Страница 9: ... 13 14 PROG INPUT is used to connect the Automatic Technology Handheld Programmer for editing control and receiver functions accessing diagnostic tools and activating special features and operating modes SBY 3 CONNECTOR is used to connect both Battery Back Up Kits and SmartSolar kits 10A FUSE 16 17 18 ...

Страница 10: ... 1 x Installation Manual Pre Assembled Single Piece C Rail NOTE The chain or belt in the one piece rail has been tensioned by the factory Do not adjust the tension of the chain IMPORTANT NOTE If a modification to the length of the track is required the adjustment must be made from the drive unit end only Pre Assembled Multi Piece C Rail Note The chain or belt in the multi piece rail has been tensio...

Страница 11: ...04 fig Adjust chain tension Move the shuttle to middle of track Use a spring scale to measure required force to pull the shuttle adjust 1 2 hex bolt to tension chain Recommended pull force 8kg 80N Screws 10 Screws Turn tracks around 9 Tension 1 2 hex bolt 8 Swing and straighten 6 Slide sleeve 7 5 Swing Slide sleeve 3 4 Cut cable tie 2 Swing and straighten Start Swing 1 ...

Страница 12: ...ular to the rail Thread the loose end of the cord through the hole in the yellow clutch lever Fig 05 Thread the cord down to red toggle and knot through the spare hole Test if secured properly by pulling back towards sprocket end to engage and the towards door end to disengage Step 3 Secure C Rail to Drive Unit Locate and insert the shaft of drive unit into the C Rail s sprocket Fig 06 Fix the two...

Страница 13: ...o 10 For a sectional panel door on tracks Fig 08 proceed with the installation from Step 5 For a one piece door on tracks Fig 09 proceed with the installation from Step 5 For a one piece door without tracks on springs Fig 10 proceed with the installation from Step 9 08 fig 09 fig 10 fig Door Sectional door with track Door Track One piece door with track One piece door without track ...

Страница 14: ...rick wall or timber lintels are solid and sound so as to form a secure mounting platform Step 7 Attach the Rail to the Wall Bracket Attach the C Rail assembly to the wall bracket with the 90mm long clevis pin and secure with the supplied snap pin Fig 13 Leavethepowerheadinitspackingboxforprotection during installation Step 8 Secure the Powerhead to the Ceiling Raise the powerhead from the packing ...

Страница 15: ... template mark a minimum of two holes and drill with appropriate size bit For a more secure fitting the wall bracket can be anchored using more than two holes Secure the bracket to the wall using IF CONCRETE OR BRICK 8mm 5 6 loxins dynabolts IF TIMBER wood screw 20 or similar min 50mm Attach the bracket and C Rail with supplied pins Fig 13 WARNING Make sure concrete brick wall or timber lintels are...

Страница 16: ...sed to the door and or door panels Step 14 Attaching the Arms FOR SECTIONAL AND ONE PIECE DOORS WITH TRACK Assemble the bent and straight arms with bolts and nuts supplied in the accessory pack Fig 20 Always use both bent and straight arms Connect the assembled arm to the bracket and the disengaged trolley with clevis and snap pins The angle A must be more than 10 Fig 21 WARNING Connecting the ben...

Страница 17: ... MINUS button when the door is near the desired closed position Single presses of the MINUS button will inch the door closed If the door overshoots press the PLUS button to move the door in the open direction When the door is at the desired close position press the SET button to record the close limit position The OPEN LIMIT LED will now flash Press and hold the PLUS button to open the door Fig 25 ...

Страница 18: ...utton 1 to inch the door towards open When happy with the close limit position press Button 2 to store this in memory Press Button 1 to open the door When approx 20mm from the desired open position press and hold Button 3 for two seconds then release Each press of Button 1 will allow you to inch the door open Keep doing this until the door reaches the desired open limit position If the door is ope...

Страница 19: ... under the door Fig 29 Press the OPERATE button to close door The door should strike the object and start to re open Step 17 2 Testing Open Cycle Press the OPERATE button to close the door Fig 28 Press again to open the door When the door reaches the half open point grab the bottom rail of the door firmly and the door should stop If the door does not reverse readily when closing or stop when openin...

Страница 20: ...RGIN SET button Fig 30 While holding the FORCE MARGIN SET button press the MINUS button Each press decreases the force margin Fig 30 The CLOSE LIMIT LED will flash each time the MINUS button is pressed to indicate a force decrease IftheCLOSELIMITLEDflashescontinuously when pressing the MINUS button this indicates that the maximum setting has been reached Test the force again as per Steps 8 1 and 8 2...

Страница 21: ...for Pet Pedestrian Mode Press and hold both the DOOR CODE and MINUS buttons Fig 35 Press one of the four buttons on the transmitter for two 2 seconds pause for two 2 seconds then press the same button again for two 2 seconds Release the DOOR CODE and MINUS buttons Press the transmitter button to test To change the default pet pedestrian door opening position refer Step 2 Step 19 4 Code a Transmitt...

Страница 22: ...r two seconds and then release Wait for 10 seconds and then press the new transmitter s button to test Step 21 1 Deleting a Stored Transmitter Code Select the transmitter you want to delete Press and hold the DOOR CODE BUTTON Fig 38 Press the transmitter button you would like to delete for two seconds pause for two seconds press again for two seconds and then release Release the DOOR CODE BUTTON T...

Страница 23: ... Beams recognise that a vehicle has left the garage The Auto close timer only starts after the P E Beam s path is broken the Auto close timer has been set If the P E path is not broken the door will remain open until the path is broken If the opener incurs a physical obstruction i e not from the P E Beams while closing the door will re open and not Auto close until the P E Beam s path is broken ag...

Страница 24: ...nstallation Manual Feed the Solar Panel s cable through black grommet located on the top of the plastic drive unit cover Connect the red wire to the Charger Board s SOLAR connector and the black wire to the SOLAR connector Fig 44 WARNING During Step 24 3 the opener will become active Step 24 3 Mount Connect the Battery Mount the Battery Box close to the opener Feed the 2 core 18awg gauge cable sup...

Страница 25: ...motion disconnect mains power the door should continue to operate as normal NOTE Wait for the door to complete its travel Press the OPERATE button or transmitter to activate the door Whilst door is in motion re connect power The door should complete the cycle as normal Step 25 3 Troubleshooting If door stops or moves very slowly under battery power the batteries may be weak or have no charge Conne...

Страница 26: ... the OPEN or CLOSE button to move the door to the desired pet mode open position Press the SET button to record the new position When activated Pet Mode drives the door to the preset position from either above or below Pet Mode s active status is indicated by both the OPEN and CLOSE LIMIT LEDs being illuminated If a Pet Mode button is pressed while the door is moving the door will stop If a Pet Mo...

Страница 27: ...eight 5500mm 16 5m2 3000mm 100 kg Minimum Clearance Bottom of C Rail to highest point of door travel 25mm Short term peak force 800N 80kg Lift force 500N 50kg Nominal force 150N 15kg Receiver type UHF 433 92 MHz AM Receiver Receiver code storage capacity 24 x 4 button transmitter codes Transmitter frequency to 433 92 MHz Coding type Multi frequency Code hopping Number of code combinations Over 4 2...

Страница 28: ... On Opening Flashing Closing Flashing Door travel stopped Flashing Flashing Door obstructed when opening Flashing Door obstructed when closing Flashing Beeps as door moves Opener overloaded Alternating flashes Alternating flashes Door in open position with Auto Close mode selected One second flashes Pet Mode Engaged On On Mains power interrupted Rapid flashes ...

Страница 29: ...lay time AUTO CLOSE TIME then SET Resets the factory default auto close delay time FORCE MARGIN SET AUTO CLOSE TIME then OPEN Each press of the PLUS button increases the light time by 10 secs FORCE MARGIN SET AUTO CLOSE TIME then CLOSE Each press of the MINUS button decreases the light time by 10 secs FORCE MARGIN SET AUTO CLOSE TIME then SET Reloads the factory default light time CLOSE for 6 secs...

Страница 30: ...on need to be reset Reset limits positions Refer Step 16 3 on page 18 Door will not open fully Door limits position need to be reset Reset limits positions Refer Step 16 3 on page 18 Courtesy light not working Faulty light Replace lamp Auto close not working PE Beam or wiring faulty PE Beam not aligned correctly PE Beam is obstructed Door obstructed when closing Auto close time not set Repair P E ...

Страница 31: ...s when the door contacts a 40mm high object placed on the floor AS3350 NOTE If the door does not operate smoothly call your installer Yearly Automatic Technology suggests you contact your installer to perform an annual door service CAUTION Frequently examine door particularly cables springs and mountings for signs of wear damage or imbalance Do not use if repair or adjustment is needed since a faul...

Страница 32: ...32 GDO 9v2 SecuraLift Owner Installation Instructions Parts Listing ...

Страница 33: ...Owner Installation Instructions GDO 9v2 SecuraLift 33 ...

Страница 34: ...h k installation adjustment or use which is not in accordance with the instructions set out in installation instruction manual l attempted or complete modification or repairs to the product carried out by a person who is not authorised or has not been trained by ATA to carry out such modification or repairs m faulty or unsuitable wiring of structure to which the product is fixed or connected n radio ...

Страница 35: ...Owner Installation Instructions GDO 9v2 SecuraLift 35 ...

Страница 36: ...lia Pty Ltd No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to change specification without notice E OE Automatic Technololgy Australia Pty Ltd ABN 11 007 125 368 6 8 Fiveways Boulevard Keysborough Victoria 3173 Australia P 1300 133 944 61 2 9722 5666 International Enquiries Only E sales ata aust com au www ata aus...

Отзывы: