5.8
Photocell Wiring
www.geniecompany.com
04-14
NOTE: Installer must enable ODC STB in calibration mode. See page 6.10.
2) To Mount Photocells: (Kit includes detailed Instructions).
• Determine location for mounting. They do not need to be directly adjacent to the door but must
be somewhere along the wall where there will be an unobstructed line between them. Fig. 9.
• They must extend out away from the wall sufficiently that no door hardware breaks the plane of the photo-beam.
1) Nominal 24 Volt DC Commercial photocells with normally open contacts can be
connected as shown in Fig. 8.
NOTE: Blue wire supplies 20 – 40VDC. Photocells used must be compatible with this voltage range.
NOTE: If no voltage is present at Blue wire, check fuse F-1 on Control board.
Monitored Photocells
Commercial Non-Monitored Photocells
1) Monitored SERIES II (STB) photocells (P/N OPAKPE.S) and Residential Safe-T-Beam® Monitored
be connected to either terminal (they are not polarity sensitive.) (Troubleshooting in Section 8)
Photocells from Genie® (P/N 37220R & 38176R.S). Fig. 7. Wiring to these photocells can be
CONTROL SIGNAL
TERMINAL STRIP
ODC
STB
ODC
STB
Figure
7
CONNECT WIRES TO EITHER TERMINAL.
(NOT POLARITY SENSITIVE)
N-O
REVERSE
N-O
REVERSE
+
-
+
-
THRU-BEAM
PHOTOCELLS
CONTROL SIGNAL
TERMINAL STRIP
RECEIVER
TRANSMITTER
EXT RADIO CONNECTOR
PWR
20-40 VDC @ 250mA
MAX. CURRENT
RELAY
GND
NOM
+ 24VDC
RADIO
Blue
Orange
Yell
o
w
Figure
8
WARNING:
Actuating the operator by using constant contact on the CLOSE button
will override non-functioning external reversing devices, including photocells.
AVERTISSEMENT:
L'activation de l'operateur en utilisant un contact constant
sur le bouton FERMER annulera les dispositifs d'inversions externes, y compris les cellules photoelectriques.
WARNING:
Photocell systems provide entrapment protection when mounted near the
doorway in such a way that the lower portion of an individual’s leg will break the photocell beam during
normal walking conditions.
AVERTISSEMENT:
Les systèmes de cellules photoélectriques fournissent
une protection contre le coincement pour le montage à proximité de la porte de manière à ce que la partie
inférieure de la jambe d'un individu ne puisse pas rompre le faisceau de la cellule photoélectrique lors de
passages normaux par la porte.
Figure 9
SERIES II (STB)
RESIDENTIAL PHOTOCELLS