6.6
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
OPEN
1) If operator is in RUN mode, press CAL/RUN key to enter calibration mode.
2) Press SCROLL key until display reads “OPEN MODE>MOM” or
“OPEN MODE>C-STP.” Figure 10.
MOM=momentary contact, meaning you press and release the
d
n
a
y
e
k
N
E
P
O
the door will continue to move
until
it reaches
its travel limit. (See NOTE)
C-STP=constant contact-stop, meaning if you release the key prior
to the door reaching its travel limit, the door will stop.
3) Press SET/CLEAR key to toggle between “OPEN MODE>C-STP” or
“OPEN MODE>MOM” on the display.
4) Press a SCROLL key to shift to a new function and lock in the setting.
5) Press CAL/RUN key to return to run mode.
CLOSE
1) If operator is in RUN mode, press CAL/RUN key to enter calibration mode.
2) Press SCROLL key until display reads “CLOSE MODE>MOM,”
“CLOSE MODE>C-STP” or “CLOSE MODE>C-REV.” Figure 10.
MOM=momentary contact, meaning you press and release the
CLOSE key and the door
will continue to move
until it reaches
its travel limit. (See NOTE)
C-STP=constant contact-stop, meaning if you release the key prior
to the door reaching its travel limit, the door will stop.
C-REV=constant contact-reverse, meaning if you release the key
prior to the door reaching its travel limit, the door will
reverse direction. (See NOTE)
3) Press SET/CLEAR key to toggle between “CLOSE MODE>C-STP” or
“CLOSE MODE>C-REV” or ”CLOSE MODE>MOM” on the display.
4) Press a SCROLL key to shift to a new function and lock in the setting.
5) Press CAL/RUN key to return to run mode.
Setting Open and Close Modes
(Constant vs Momentary Contact)
OPEN MODE MOM
Figure 10
NOTE: Momentary contact (MOM) or Constant Reverse (C-REV) may not be used
unless both the OPEN and CLOSE Limits have been set.
In situations where an external reversing device is either not installed or not
operating properly, Constant Contact (C-STP) MUST BE USED.
NOTE: During adjustment of a Travel Limit, the Open and Close Modes will
automatically fail-safe to Constant Contact until the Limit has been set or reset.
At that time the Open and Close Modes will revert to their previous setting.
CLOSE
CAL
RUN
S O L
SCROLL
SE
C EA
OPEN
SET
CLEAR
SCROLL
LOSE
T
CAL
RUN
SC L
CLEA
EN
LO E
CAL
RUN
ROLL
C L
SCROLL
SE
L AR
EN
CLOSE
SET
CLEAR
SCROLL
CAL
RUN
www.geniecompany.com
04-14
WARNING:
Before momentary contact control can
be used on the CLOSE button, a monitored external reversing device
such as a photocell system or sensing edge switch must be used.
See pages 5.8-5.10 for installation of entrapment protection devices.
AVERTISSEMENT:
Avant d'utiliser la
commande à contact momentané sur le bouton FERMETURE, un
dispositif d'inversion externe surveillée tel qu'un système de
cellule photoélectrique ou un commutateur de détection de bord
doit être utilisé. Voir l'installation des dispositifs de protection
contre le coincement en pages 5.8-5.10.