CAL
RUN
SET
CLEAR
SCROLL
CROLL
CAL
RUN
6.3
1) If operator is in RUN mode, press CAL/RUN key to enter calibration mode.
2) Press Scroll key until display reads “BRAKING RATE >#.” where # is the
deceleration rate, ranging from 0 to 9. 0=Max. braking. 9=Min. braking.
Figure 6.
3) Press SET/CLEAR key to toggle between 0 and 9—one digit at a time.
4) Pick a value and operate the door. Adjust as necessary.
5) Press a SCROLL key to shift to a new function and lock in the setting.
6) Press CAL/RUN key to return to run mode.
Setting Braking Rate
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
BRAKING RATE 0
Figure 6
www.geniecompany.com
01-14
S
Содержание GCL-J&H 1/2HP
Страница 2: ...THIS PAGE LEFT BLANK...
Страница 66: ...THIS PAGE LEFT BLANK...
Страница 67: ...THIS PAGE LEFT BLANK...
Страница 68: ...1 Door Drive Mt Hope Ohio 44660 www geniecompany com 1 1 1 8 4 5 5 0 2 3 5 1...