5.2
1)
Remove LINE VOLTAGE INPUT PLUG and install proper
fittings and 1/2”conduit.
2)
Route proper LINE VOLTAGE wires into operator.
3)
Locate LINE INPUT terminals on circuit board. Using
correct connectors, attach wires to LINE INPUTS, and GROUND
terminal.
Keep low voltage and line voltage wires separate.
Route all line voltage wires as shown.
Plug all unused conduit holes.
P
HIGH
VOLTAGE
INPUT PLUGS
(Right & Left)
ROUTE HIGH VOLTAGE WIRING
IN THE SHADED AREA AS SHOWN
LINE INPUT
TERMINALS
LINE
GROUND
LINE INPUT
TERMINALS
LINE
GROUND
ROUTE HIGH VOLTAGE WIRING
IN THE SHADED AREA AS SHOWN
LINE IN
LINE IN
POWER CONNECTIONS
L1
L2
L3
GND
LINE 1
LINE 2 LINE 3
Three Phase
Single Phase
HIGH
VOLTAGE
INPUT PLUGS
(Right & Left)
Figure 1
Line Voltage Wiring Fig. 1
www.geniecompany.com
04-14
L1 / L1
N / L2
GND
LINE
(HOT) NEUTRAL
LINE 1
LINE 2
115V
208V
230V
Содержание GCL-J&H 1/2HP
Страница 2: ...THIS PAGE LEFT BLANK...
Страница 66: ...THIS PAGE LEFT BLANK...
Страница 67: ...THIS PAGE LEFT BLANK...
Страница 68: ...1 Door Drive Mt Hope Ohio 44660 www geniecompany com 1 1 1 8 4 5 5 0 2 3 5 1...