This section describes the additional configuration steps required for some Samsung units to
work in Omnicast.
This section includes the following topics:
•
•
"Configure Samsung ONVIF units"
Configure SNP-3750 units
To configure the video stream resolution for SNP-3750 units using either MPEG-4 or MJPEG
streaming:
1
Open the unit’s Web page.
2
Click
Video Setup > Streaming
.
3
Choose the desired resolution from the
Unicast Image Resolution
drop-down list.
If using MJPEG streaming, you must also modify the video resolution on the machine that is
running the Config Tool.
4
On the Config Tool machine, navigate to the SNP-3750 cam file, located in:
C:\Program
Files\Common Files\DVR Software 4.x\Extensions\Cam Files\Samsung SNP3750.cam
on 32-
bit machines, and
C:\Program Files (x86)\Common Files\DVR Software 4.x\Extensions\Cam
Files\Samsung SNP3750.cam
on 64-bit machines.
5
Open the
SNP3750.cam
file in Notepad.
6
Locate the following line:
<MjpegURLs>public/video.cgi?ch=1&resolution=cif</MjpegURLs>
7
Replace
cif
with the desired resolution: qcif, cif, or 4cif.
NOTE
Use lowercase text only.
8
If the unit is already part of your Omnicast system, remove and delete the unit from Omni-
cast, and add it using the Config Tool station where the cam file has been modified.