Bosch
genetec.com | Omnicast Video Unit Configuration Guide 4.8 SR3
30
EN.100.007-V4.8.C3.(1)
Configuring Bosch Divar 700 DVRs
Perform the following configuration steps in the Bosch Divar Web page before adding the
associated units in Omnicast.
•
•
•
"Configure recording settings"
Configure Analog cameras
If there are analog cameras connected to the Bosch Divar 700, you must enable the video input
for those units in the Divar’s Web page.
Before you begin:
Connect the video output of the analog cameras to the Video In connections
on the Divar. The number of connectors depends on the type of Divar you have. The maximum
number of analog cameras you can have is 16.
1
Open the Bosch Divar 700’s Web page.
2
Click
Configuration > Video & Audio
.
3
Click the numbered tab corresponding to the Divar Video In connector an analog camera is
connected to.
4
In the
General
tab, select the
Enable video input
option.
5
To enable PTZ on the camera, click the
Control
tab, and select the
Enable PTZ
option.
6
Select a Protocol from the drop-down list.
7
Select a Device address.
NOTE
Make the address the same as the Divar camera input.
8
for each analog camera connected to the Divar.
9
Click
Save > Close
.
10
If the analog cameras are already part of your Omnicast system, restart the Divar unit in
order for the cameras to become visible in Omnicast.
Configure network cameras
If there are network cameras connected to the Bosch Divar 700, you must configure those units
in the Divar’s Web page.
NOTE
The maximum number of network cameras you can have is 32. If you have analog
cameras, connect them to the Divar Video In connectors starting at connector 1, and use the
remaining connectors for the network cameras (for example, if connectors 1-7 are analog
cameras, connectors 8-32 could be network cameras).
1
Open the Bosch Divar 700’s Web page.
2
Click
Configuration > Video & Audio
.
3
Click the numbered tab corresponding to a Video In connector for a network camera.