Interlogix
genetec.com | Omnicast Video Unit Configuration Guide 4.8 SR3
51
EN.100.007-V4.8.C3.(1)
Enable software motion detection
To enable software motion detection for Interlogix Discovery 105-E (UVE-101) units in
Omnicast, additional configuration is required in Config Tool.
1
From the
Physical view
in Config Tool, select the camera to configure.
2
Click the
Motion detection
tab.
3
Set the
Sensitivity
slider to
20
%.
4
Click the
Advanced
button.
5
From the
Preset
drop-down list in the
H.264 Advanced motion detection settings
dialog
box, select
Custom
.
6
Under
Custom,
set the following values:
Luma weight: 5
Chroma weight: 0
Vectors weight: 0
Macroblocks weight: 100
7
Click
Close
, and click
Apply
.
For more information about advanced motion detection settings, see “Advanced H.264 Motion
Detection” the
Omnicast Administrator Guide
.
Configuring VisioWave units
The Interlogix VisioWave driver can control multiple Interlogix units and PTZ motors. You must
add and configure Interlogix VisioWave units using the
Central Configuration Server
application.
Before you begin:
Make sure the Interlogix
Central Configuration Server
is installed.
Best practice:
Perform these configuration steps before adding the unit to the Archiver.
•
•
•
Add VisioWave units
1
Open the
Central Configuration Server
in Internet Explorer.
2
Click
Equipment > New Video Equipment
.
3
Enter the following information:
a
In the
Equipment
name field, type a name for the unit.
b
In the
IP Address
field, type the IP address of the unit.
c
From the
Product Hardware Range
drop-down list, select the unit type (for example,
EVOLUTION HD, or DISCOVERY 300).
NOTE
The number of inputs available depends on the unit type.