Configure trickling for Axis units
To use trickling with Axis units, it is recommended to configure the following settings in Con-
fig Tool and on the unit’s Web page.
For more information about configuring trickling, see “Trickling” in the
Omnicast
Administrator Guide
.
Best practice:
To improve readability when trickling with Axis units, use an SDHC memory
card or an SD card with a speed class of four or higher, and use H.264 streaming. For more
information about which SD cards are recommended for use with your unit, see your Axis doc-
umentation.
1
From the
Physical view
in Config Tool, select the Archiver to configure.
2
Click the
Trickling
tab, and click
Properties
.
3
In the
Trickling Properties
dialog box, do the following:
a
Select the following
Trickling filters
:
Motion
and
Bookmarks
.
b
Set the
Event download pre-roll
slider value to
6
seconds or higher.
c
Set the
Event download post-roll
slider value to
6
seconds or higher.
d
Click
OK
.
4
From the
Physical view
in Config Tool, select the Axis camera to configure, and click the
Recording
tab.
5
Clear the selected
Archiving schedules
, and click
Apply
.
6
Click the
Motion detection
tab.
7
From the
Motion detection
drop-down list, select
Full screen (Unit)
.