OTN
genetec.com | Omnicast Video Unit Configuration Guide 4.8 SR3
65
EN.100.007-V4.8.C3.(1)
Enable MPEG-4 start code lookup offset
MVIDIPv4 units sometimes develop offset start codes in the MPEG-4 video stream. As a solu-
tion, the MPEG-4 start code lookup value must be increased so that the video stream will be
found in Omnicast. This advanced setting must be modified on the Client and Server machines
for proper archiving and video decoding.
1
Open the
Registry Editor
in Windows.
2
Navigate to one of the following folders:
If you are using a 32-bit system:
HKEY_LOCAL_MACHINE\SOFTWARE\Gene-
tec\Genetec Omnicast4.x.
If you are using a 64-bit system:
Computer\HKEY_LOCAL_MACHINE\SOFT-
WARE\Wow6432Node\Genetec\Genetec Omnicast4.x.
3
Double-click the
Mpeg4DemuxStartCodeLookupOffset
REG_DWORD.
4
In the
Value data
field, type
100
.
This changes the start code value for video frames to have a lookup of
100
bytes, in case the
offset increases with time.
5
Click
OK
.
Restart Omnicast services to apply your changes.