15.1.3
Isolated single
-
ended or Isolated unbalanced differential input
GND
(+)
900 k
100 k
(+)
(–)
U
diff
U
iso
(–)
Isolation
Barrier
U
iso
Non-isolated
system
Figure 15.4:
Isolated single
-
ended or Isolated unbalanced differential amplifier
l
Also referred to as
unbalanced
,
isolated
or
unbalanced differential
amplifier
l
None of the inputs are connected to ground for safety and to avoid ground
loops
l
Typically used in isolated DAQ systems
l
Often identified by the use of a single PLASTIC (isolated) BNC
connector
l
Used in GEN DAQ ISOLATED Basic amp
l
Can perform
DIFFERENTIAL MEASUREMENTS with different limitations
and options, compared to a differential grounded amplifier
.
GEN3t
382
I3995-3.1 en HBM: public
Содержание GEN3t
Страница 1: ...Portable Data Recorder GEN3t English User Manual I3995 3 1 en HBM public...
Страница 4: ...4 I3995 3 1 en HBM public...
Страница 51: ...33 46 7 70 IEC 61010 1 2010 IEC EN 50110 1 EN 50110 2 50 120 GEN3t I3995 3 1 en HBM public 51...