65
Model FL4000H
Remote Power Supply
3,000 ft (930 m), maximum 20
loop and 24 VDC minimum (Section 3.6 ).
8.3 Regulatory Information
8.3.1 Approvals
Approvals
Standard
Configuration
10
HART
ATEX
X
X
IECEx
X
X
CSA X
X
FM X
X
ULC X
X
HART Communication Foundation (HCF)
X
CPR (EN 54-10)*
X
X
INMETRO X
X
BV Type Ap MED
X
X
IEC 61508 to SIL 3, 2 or 1
X
X
*
Listed as Class 1 for High and Medium Sensitivity and Class 2 for Low Sensitivity
8.3.2 Classification
Area
and Protection Methods
The FL4000H is certified as follows:
Protection Method: Explosion proof, Flame proof, Dust-Ignition proof
Temperature Class: T5 (T
amb
= -40°C to +80°C)
Area Classifications:
Class I, Division 1, Groups B, C, and D
Class II, Division 1, Groups E, F, and G
Class
III
Zone 1, Group IIC per ATEX / IECEx
Zone 21, Group IIIC per ATEX / IECEx
Ex d IIC T5 Gb, Ex tb IIIC T100°C Db
EMC/EMI:
EMC Directive (2014/30/EU)
EN 50130-4, EN 61000-6-4
Environmental Protection: Type 6P Enclosure, IP66/67
10
Dual Modbus with or without relays