Models FL3100H/3101H
37
5.7.7 Software
Revision (05H)
A read returns the software revision of the FL3100H / FL3101H in 2 ASCII characters. (REV “A”
appears as a blank and the letter A).
5.7.8 COPM
Fault (06H)
A read returns the type of Continuous Optical Path Monitoring (COPM) Fault which is an UV
COPM Fault or an IR COPM Fault, or both. The UV COPM and/or the IR COPM Faults indicate
that the UV and/or IR windows are dirty and need to be cleaned, or that there is a hardware
problem with the UV and/or IR detection circuitry.
UV COPM Fault = 01 (Lo Data Byte)
IR COPM Fault = 02 (Lo Data Byte)
The High Data Byte is Not Used.
5.7.9 EEPROM Override (07H)
A read indicates the status of the EEPROM Override bit. A write command changes the state of
the EEPROM Override bit. When the EEPROM Override bit is enabled, the options for the
Detector Sensitivity, Relay Delay, Relay Latching/Non-Latching and Relay Energized/Non-
Energized features are now controlled by the data stored in the EEPROM and are no longer
controlled by the 8-position DIP switch located on the bottom of the Power/Relay Board. When
the EEPROM Override bit is disabled the options are under the control of the 8-position DIP
switch. The EEPROM Override bit is located in the LSB of the Low Data Byte and the High
Data Byte is not used.
Function
Bit (LSB)
Access
Enable 1
Read/Write
Disable
0
Read/Write
Table 23: EEPROM Override
NOTE:
By grounding the ALARM TEST input during power-up cycle (approximately 10
seconds), the FL3100H / FL3101H will disable the EEPROM Override and set the Bit =
0, thus enabling the 8-position DIP switch.
5.7.10 Options (08H)
A read returns the status of the settings for the Detector Sensitivity, Relay Delay, Relay
Latching/Non-Latching and Relay Energized/Non-Energized features either from the Options
Dipswitch or the EEPROM depending on the setting of the EEPROM Override bit listed above.
A write command changes the settings for the EEPROM only when the EEPROM Override bit
is set.
EXCEPTION -
If an attempt to change the EEPROM Options is made while the EEPROM
Override bit is not set, then the unit shall return an Exception Code 01 (Illegal Function).
Содержание FL3101H
Страница 2: ...Models FL3100H 3101H ii This page intentionally left blank ...
Страница 22: ...Models FL3100H 3101H 15 Figure 14 P N 71072 Rear View Mounting Bracket Drawing ...
Страница 24: ...17 Models FL3100H 3101H Figure 17 FL3100H FL3101H Field Terminations Figure 18 Detector Housing and Base ...
Страница 70: ...63 Models FL3100H 3101H 10 7 Final Assembly Figure 24 P N 71450 FL3100H UV IR Final Assembly ...
Страница 71: ...Models FL3100H 3101H 64 Figure 25 P N 71451 FL3101H UV Final Assembly ...