manualshive.com logo in svg
background image

BS-506/LITHIUM

BATTERY OPERATED 

SMOKE ALARM

Thank you for your trust in our products  

Olympia Electronics - European manufacturer

921506001_09_007

4

5

European

manufacturers

Signaling Overview

1 Red per 344 sec

None

Device

functioning properly

1 Red per sec

Alarm pattern

Device under test

1 Red per sec

Alarm Pattern

Smoke detected

1 Red per 10 sec

None

9 min

decreased sensitivity

3 Yellow per 43 sec

None

Exited an

alarm mode

None

Replace batteries

None

3 short signals

per 43 sec

Replace the

smoke alarm

1 short signal

per 43 sec

ALARM

TEST

HUSH

ALARM MEMORY

LOW BATTERY

FAULT WARNING

NORMAL

5. Test the correct operation of your smoke alarm as described in Device Test 

paragraph.  If  no  sound  is  generated,  the  smoke  alarm  must  be  replaced 
immediately!

3. Replace  the  old  batteries  by  a  new  pair.  Use  recommended  batteries  for 

more reliable operation.

2. Clean the device as described in maintenance paragraph.

1. Remove  smoke  alarm  from  mounting  plate  following  Step  1  of  the 

installation instructions.

4. Place  the  smoke  alarm  on  the  Mounting  plate  and  secure  it  by  turning  it 

clockwise.

The  WEEE  symbol  means  that  this  product  and  batteries  must  be  disposed 

separately from other household waste. When they reach their end of 
life,  take  them  to  a  designated  waste  collection  point  in  your  area  to 

guarantee a safe disposal or recycling. Protect the environment, human 

health and natural resources!

False alarm is often caused by dust or steam. 
After a batteries replacement, the device performs an auto-adjusting process 
in 8 hours period to establish its operation. If false alarm happens within this 
period, it is important to clean the smoke alarm as described in maintenance 
paragraph.

Battery Replacement

 

Recycling and Desposal

Troubleshooting

921506001_09_007

Visible indication

(flashes)

Operating Mode

Acoustic Signal

Comment

IP

20

10 years

Battery

Life

Optical

85dB

EN14604

2008

BS-506/LITHIUM

10 years

Technical Characteristics

0.110 dB/m

Optical and Acoustic > 85dB (A) at 3 m

Yes
Yes
Yes

Ceiling

No

Optical

IP20

EN14604-2008

o

0 to 45  C

Up to 93% 

ABS/PC, PC

Ø130 x 43 mm

185gr.

3 years

 (1 

year for the battery

)

SMOKE CONCENTRATION SENSITIVITY

INDICATORS

ALARM SILENCE FACILITY

LOW BATTERY WARNING
LOW BATTERY SILENCE FACILITY
MOUNTING LOCATION
INTERCONNECTABLE
DETECTION METHOD

PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE

DEGREES OF COVER PROTECTION

RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION

WEIGHT
GUARANTEE

POWER SUPPLY
BATTERY LIFE

Replaceable batteries: 2x AA Lithium FR6 (L91)

Olympia  Electronics  guarantees  the  quality,  condition  and  operation  of  the 
goods. The period of warranty is specified in the official catalogue of Olympia 
Electronics and also in the technical leaflet, which accompanies each product. 
This  warranty  ceases  to  exist  if  the  buyer  does  not  follow  the  technical 
instructions included in official documents given by Olympia Electronics or if the 
buyer modifies the goods provided or has any repairs or re-setting done by a third 
party, unless Olympia Electronics has fully agreed to them in writing. 

Products 

that have been damaged can be returned to the premises of our company for 
repair or replacement, as long as the warranty period is valid.

Olympia Electronics reserves the right to repair or to replace the returned goods 
and to or not

 

charge the buyer depending on the reason of defection. Olympia 

Electronics reserves the right to charge or not the buyer the transportation cost.

Warranty

72

nd

 

km

O

.

N

.

R

Thessaloniki-Katerini

P.C. 60300 P.O. Box 06 Εginio Pierias Greece

www.olympia-electronics.com

[email protected]

BS-506/LITHIUM

Battery Operated 
Smoke Alarm

1922

21

EN 

14604:200

8

DoP: 921506001_59_001

EGINIO
PIERIAS
60

300

 

GREECE

Отзывы: