SMOKE ALARM R9 

Photoelectric Smoke Alarm with 9V Battery & Test Button 

SMOKE ALARMS 

INSTALLATION INSTRUCTIONS 

 

PLEASE NOTE: 

READ ALL INSTRUCTIONS BEFORE INSTALLATION. NO USER SERVICEABLE PARTS INSIDE THIS SMOKE ALARM. 

Specifications:

 

Features: 

Main Power Source 
Sensing Type 

Sensitivity to smoke 
Operation Current 
Temperature Range 
Humidity Range 
Sound Level Alarm 
Condition Visual 
Indicators 

Approval 

9V Battery 
Type A Photoelectric smoke alarm 
- contains NO radioactive material 
0.08-0.2db/m 

<

20mA operation (In Alarm) 

0°C to 40°C 

 

10% to 90%

AS 3786:2014, UL S36341 

• DC operated photoelectric type smoke alarm

 

• Photoelectric sensor for slow

smouldering fires

• Test & Hush button

• Environmentally friendly non-radioactive

technology High and stable sensitivity

• Quick fix mounting bracket for easy installa

tion

 

 

• Extra loud alarm sound over 85 dB
• Low-battery and battery missing

warning indicators

• Auto reset when smoke clears

IMPORTANT: 

This  manual  contains  important  information  about  the  installation  and  operation  of  your  smoke  alarm.  Please  read  carefully  before 

installation

 

and keep for future reference. Please ensure that this leaflet remains in the household where the alarm is installed. 

WARNING: 

This smoke alarm is designed to alert you to the presence of smoke. It cannot prevent a fire. There are hazards  involved which smoke 

alarms  may  not  be  effective  against,  such  as  smoking  in  bed,  explosions,  etc.  The  ultimate  responsibility  for  fire  protection  rests  with  you,  this 
responsibility  includes  escape  planning,  safety checks  and  an  effective  warning  system. In  case  of fire,  a  well-placed,  properly  looked  after  smoke 
alarm may provide a few vital seconds so that you can escape and call the fire brigade. 

IMPORTANT SAFETY INFORMATION 

 

Installation of Smoke Alarms: 

 

1. The battery must be operational for correct alarm function. To test the

battery, press the test button on this smoke alarm.

2. The test button accurately tests all smoke alarm functions. DO NOT

use any other test method.

3. DO NOT remove or disconnect battery to silence unwanted alarms, this

will remove your protection. Press hush button or open windows to
ventilate the smoke alarm to silence it.

4. This smoke alarm is designed to be used 

inside a single dwelling

 only. In

buildings with several 

dwellings/units, each

 individual living unit should

have its own smoke alarms. DO NOT install in non-residential buildings.

5. Install a smoke alarm on every level of the home.

6. 

Smoke 

alarms can only sound their alarms when they detect smoke. Smoke 

alarms detect combustion particles in the air. They do not sense heat, flame 
or gas. This 

smoke

 alarm is designed to give an audible warning of a 

developing fire

; however, many

 fires are fast burning, explosive or

intentional, others

 are caused by carelessness or safety hazards. Smoke

may not reach the smoke alarm quickly enough to ensure safe escape.

7. Smoke alarms have limitations, this smoke alarm is not foolproof and is

not warranted to protect lives or property from fire. Smoke alarms are
not a substitute for insurance and homeowners and renters should
insure their lives and property. In addition, it is possible for the smoke
alarm to fail at any time, for this reason, you must test the smoke alarm
weekly and replace every 10 years.

Locating and Positioning of Smoke Alarms: 

 

1

From 

the 

back  of  the  smoke  alarm, 

remove the mounting plate by turning 
it counter clockwise.

2.  Secure plate to ceiling or wall 

with mounting screws 
appropriate to the surface on 
which the unit is to be mounted.

3.

Connect new 9-volt battery to battery 
connector inside battery

 

pocket. Be 

sure battery is securely

 

connected. 

The red LED may blink

 

briefly when 

battery is installed.

4.

 Position smoke alarm to 
mounting plate and turn 
clockwise to lock into place.

5

Push test button to test smoke 

alarm. See OPERATION, TESTING 

Mounting 
Plate 

Screw 

9V Battery 

Alarm Unit 

Turn counter clockwise to 

 

   tuninstall and deactivate  

This smoke alarm is a single station photoelectric alarm and should NOT be connected 

Ceiling Mounting 

to other smoke alarms. 

As hot smoke rises and spread out, it is advisable to mount on a ceiling in a central po sition. 

If your dwelling is on a single storey, for minimum protection you should fit an alarm in  Avoid areas where there is no air circulation. E.g., Corners of rooms and keep away from 
the hallway between the living areas (incl. Kitchens) and sleeping areas. Place it as 

items which may prevent the free flow of air. Place the unit at least 300mm from and light 

near to the living areas as possible and ensure the alarm is audible when the 

fitting or decorative object which might obstruct smoke / heat entering the alarm. Keep at 

bedrooms are occupied. 

least 300mm away from walls. See Figure 3i 

If your dwelling is multi-storey, for minimum protection one alarm should be fitted at 

 

the bottom of the staircase with further alarms fitted on each upstairs landing. This 

Wall Mounting 

includes basements but excludes crawl spaces and unfinished attics. 

Do not mount tight into the corners. Put the top edge of your smoke alarm 

    300mm below the ceiling. Keep at least 300mm from room corners. See Figure 3i 

NOTE: 

For maximum protection

an alarm should be fitted in every room (except 

 

kitchen, bathroom, and garage). 

On a Sloping Ceiling 

In areas with sloping or peaked ceilings install your Smoke Alarm 900mm from the highest 

DO NOT FIT AN ALARM IN THE KITCHEN or BATHROOM, as cooking fumes or steam 

point measured horizontally because 

“dead air” at the apex may prevent smoke from 

may trigger the alarm. 

reaching the unit. See Figure 3ii. 

DO NOT FIT ALARM IN A GARAGE, as exhaust fumes are likely to set it off. 

SINGLE-STOREY RESIDENCE, APARTMENT, MOBILE HOME

MULTI-STOREY RESIDENCE 

 

APEX OF 
SLOPING 

min

 

500mm

1500mm 

CEILING 

500mm

min

 

max

 

DEAD 

AIR SPACE 

BEST 

BEST 

HERE 

HERE 

HEAT & SMOKE 

Figure 3ii 

FROM FIRE 

CEILING / WALL JUNCTION 

CEILING 

300mm min 

HEAT & 

DEAD AIR 

SPACE 

SMOKE 

m

i

n

3

0

0

m

m

6

0

0

m

m

FROM 
FIRE 

BEST 

NEVER 

HERE 

HERE 

ACCEPTABLE HERE 

Figure 3i

SIDE WALL 

BEDROOM 

W/C 

BATH 

LOUNGE ROOM 

BED

 

HALL 

BED 

ROOM

 

ROOM 

KITCHEN 

LIVIN

G

 

BEDROOM 

BEDROOM 

ROOM 

KITCHEN 

DINING 

BASEMENT

 

Smoke alarms for minimum protection. 

Smoke alarms with hush features recommended 

Smoke alarms for additional protection. 

for additional protection 

 

85dB at three metres minimum 

Audible signal pattern (ISO 8201) 

Red LED for warning and low

battery indication

 600mm mi

n

300mm mi

n