Maintenance
34
Owner’s Manual for 50 Hz Air-Cooled Generator Sets
•
Do not place tools or metallic objects on top of bat-
tery.
•
Remove all jewelry, including watches, rings, and
other metal objects.
•
Use tools with insulated handles.
•
If electrolyte contacts the skin, wash it off immedi-
ately with water.
•
If electrolyte contacts the eyes, immediately thor-
oughly flush with water and seek medical attention.
•
Wash down spilled electrolyte with an acid neutral-
izing agent. A common practice is to use a solution
of 454g (1 lb) bicarbonate of soda to 3.8 L (1 gal) of
water. Add bicarbonate of soda solution until evi-
dence of reaction (foaming) has ceased. Flush
resulting liquid with water and dry area completely.
•
DO NOT smoke when near battery.
•
DO NOT cause flame or spark in battery area.
•
Discharge static electricity from the body before
touching the battery by first touching a grounded
metal surface.
Battery should be regularly inspected per the
. Contact an IASD for assistance if necessary.
Inspecting the Battery
Proceed as follows to inspect battery:
1.
Perform “To turn the generator set OFF” in
ator Set Enable/Disable Procedure
.
2.
Remove front access panel and intake side panel
as described in
and
.
3.
See
. Disconnect white battery charger
cable.
Figure 4-7. Disconnecting Battery Charger Cable
4.
See
. Inspect battery posts and cables
for tightness and corrosion. Tighten and clean as
necessary.
Figure 4-8. Battery Cables
5. (Unsealed batteries only):
Completely disconnect
battery. Check battery fluid level and, if necessary,
fill with distilled water only.
DO NOT
use tap water.
Have an IASD or a qualified service technician ver-
ify the state of charge and condition.
6.
Connect battery cables and install intake side
panel and front access panel when inspection is
complete.
7.
Perform “To turn the generator set back ON” in
Generator Set Enable/Disable Procedure
Always recycle batteries in accordance with local laws
and regulations. Contact your local solid waste collection
site or recycling facility to obtain information on local
recycling processes. For more information on battery
recycling, visit the Battery Council International website
at:
.
Cleaning the Sediment Trap
The sediment trap removes contaminants (moisture and
fine particles) from gaseous fuels before they enter the
fuel regulator. Accumulated moisture and particles must
be emptied from the sediment trap per local codes and
guidelines.
Proceed as follows to clean sediment trap:
1.
2.
Remove intake side panel.
3.
Turn generator set fuel supply off.
4.
See
. Unscrew and remove sediment
trap cap (A).
ISO000228
Always recycle batteries at an official
recycling center in accordance with all
local laws and regulations.
002389
–
+
001832
Содержание G0071450
Страница 4: ...iv Owner s Manual for 50 Hz Air Cooled Generator Sets...
Страница 16: ...Safety Information 10 Owner s Manual for 50 Hz Air Cooled Generator Sets This page intentionally left blank...
Страница 32: ...Operation 26 Owner s Manual for 50 Hz Air Cooled Generator Sets This page intentionally left blank...
Страница 47: ......