L
NAPCO Security Systems
X
GEM-P3200 Programming Instructions
WI818D 8/00
!
Page 9
GEM-RP1CAe2
Ke
yp
ad
: Use
r Codes
Enter User Codes
(Press the
(
A
)
button to set cursor.)
Enter up to 48 User Codes with User Options, Authority Level and Access
Control Options (if necessary) for each code. Refer to the tables below and
on the next page for available data entries for User Options, Authority Level
and Access Control Options.
Note:
All 48 Users must be assigned to areas
in “Enable User Code by Area” (Address 2500-2547) in Direct Address
Programming. By default, only User 1 is enabled in Area 1 and Area 2.
User 2 - 8 are enabled in Area 1 and user 9 - 16 are enabled in Area 2.
!
Press the (
A
) button to set the cursor to the User Code. Use the number buttons
1
through
9
to
enter a code of up to 6 digits. Enter up to 6 digits (4 digits is recommended) in the first six boxes from left to right for
each user code. Valid entries are: 0-9.
Note:
Press the
0
button for a zero. No blank spaces in between; leave
blank (•) any trailing boxes. If an “Ambush Code” (Address 0495) is entered,
do not
program the first two digits of ANY
User Code as the same digits entered for the “Ambush Code”.
!
If the programmed code is less than 6 digits, press the
A
button to set the cursor to the OPTION/LEVEL. Refer to
the tables below for the available User Option and User Level data entries. Enter the user options data in the left digit.
Enter the level data (with arming options, if any, added) in the right digit.
Note:
For entries greater than 9, press the
G1
buttons through the
G5
buttons for B through F, respectively.
!
For Keypad Access Control, press the
A
button once again to program applicable keypads. Refer to the tables
below, use the number buttons to enter the data for Keypad 1–4 in the right digit; and the data for Keypad 5–7 data in
the left digit. (Press the
0
buttons for blank.)
User# User Code Option
Access
/Level
Control
ENTER USER CODE
U01 123___ -F3 -__
USER OPTIONS
USER CODE
(UP TO 6 DIGITS)
USER
OPTION
USER
LEVEL
ACCESS CONTROL
KEYPADS
DATA
ENTRIES
AUTHORITY
LEVEL
CODE
TYPE
blank (•)
NONE
ARM/DISARM
1
LEVEL 1
ARM/DISARM
2
LEVEL 2
ARM/DISARM
3
LEVEL 3
ARM/DISARM
4
NONE
ARM ONLY
5
LEVEL 1
ARM ONLY
6
LEVEL 2
ARM ONLY
7
LEVEL 3
ARM ONLY
8
NONE
SERVICE
9
LEVEL 1
SERVICE
0
LEVEL 2
SERVICE
B
LEVEL 3
SERVICE
Note:
“Y” indicates option is enabled.
USER OPTIONS
DATA
ENTRIES
BLOCKED
VIEW
USER
PROGRAM
BYPASS OVERVIEW
blank (•)
DISABLED
1
Y
2
Y
3
Y
Y
4
Y
5
Y
Y
6
Y
Y
7
Y
Y
Y
8
Y
9
Y
Y
0
Y
Y
B
Y
Y
Y
C
Y
Y
D
Y
Y
Y
E
Y
Y
Y
F
Y
Y
Y
Y
Note:
“Y” indicates option is enabled.
ACCESS CONTROL KEYPADS
DATA
ENTRIES
K.P. 1 K.P. 2 K.P. 3 K.P. 4
blank (•)
NONE
1
Y
2
Y
3
Y
Y
4
Y
5
Y
Y
6
Y
Y
7
Y
Y
Y
8
Y
9
Y
Y
0
Y
Y
B
Y
Y
Y
C
Y
Y
D
Y
Y
Y
E
Y
Y
Y
F
Y
Y
Y
Y
Example:
Enter a code of “123456” as
“123456” (from left to right).
Note:
“Y” indicates option is enabled.
ACCESS CONTROL KEYPADS
DATA
ENTRIES
K.P. 5 K.P. 6 K.P. 7
blank (•)
NONE
1
Y
2
Y
3
Y
Y
4
Y
5
Y
Y
6
Y
Y
7
Y
Y
Y
8
9
Y
0
Y
B
Y
Y
C
Y
D
Y
Y
E
Y
Y
F
Y
Y
Y