L
NAPCO Security Systems
X
GEM-P3200 Programming Instructions
WI818D 8/00
!
Page 65
NAPCO Security Systems, Inc.
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, call toll free: (800) 645-9445
For direct line to Technical Service, call toll free: (800) 645-9440
Internet: http://www.napcosecurity.com
Ke
yp
ad
Configura
tion Mode
: Conf
iguring the Key
p
ads
Configuring the GEM-RP2ASe2 and GEM-RP3DGTL Keypad
Up to 7 GEM-RP2ASe2 and/or GEM-RP3DGTL keypads may be connected to the panel (Keypads 1–7). Each must
be configured for a keypad address. In addition, the keypad may be configured to disable (a) touchpad backlight; (b)
LCD backlight; and (c) entry sounder. Keypads are configured by the proper selection of jumpers. Refer to the label
on the circuit board insulation paper for jumper locations and a summary of settings.
KEYPAD ADDRESS
If more than one keypad is installed:
!
Each must be assigned a unique address (that is, no two keypads may
be numbered alike).
!
Keypads must be addressed consecutively (that is, missing numbers are
not permitted).
!
Only Keypad No. 1 may be used for programming. (However, for ease of
programming, it is recommended that a GEM-RP1CAe2 be selected as
Keypad #1.)
Assign the keypad address number by selecting Jumpers J1–3 in
accordance with the table at left.
*Note:
(1) Keypads are factory supplied with no jumpers installed
and as such are automatically configured as Keypad No. 1. (2) Only
one keypad in the system may be configured as Keypad No. 1,
otherwise none will function.
TOUCHPAD BACK LIGHT
Cut Jumper A to disable touch pad backlighting to conserve 11mA standby current.
LCD BACKLIGHT
Cut Jumper B to disable LCD backlighting.
DISABLE SOUNDER
Cut Jumper C to disable the sounder. (Do not disable in UL applications.)
KEYPAD
NUMBER
1
2
3
4
5
6
7
1
2
3
OFF or
ON*
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
KEYPAD NUMBER
PARK
STORE SPARE
JUMPER AT THIS
POSITION