X
GEM-P3200 Programming Instructions
L
NAPCO Security Systems
WI818D 08/00
!
Page 8
Central Station Receiver 1 Account Number
Enter an account number of up to four digits. Use number buttons
1
through
9
for digits 1–9.
NOTE:
Press the
0
button for a zero and
press the
G 0
buttons for a blank space (•).
G 1
through
G 5
for letters B–F, respectively. Press
J
to save . Press NEXT
(
E
) button to proceed.
NOTE:
Central Station Receiver 2 and 3 Account Numbers can only be
entered in Direct Address Programming. See CS Reporting Options.
Central Station Receiver 1 Format
From the table below, enter the central station's receiver format. Use
number buttons
1
through
9
.
NOTE:
Press the
0
button for
a zero. and press the
G 0
buttons for a blank space (•). Press
G 1
through
G 4
for letters B–E, respectively.
Press
J
to save. Press NEXT (
E
) button to proceed.
DATA
ENTRY
CS RECEIVER 1 FORMAT
blank(•) Ademco Slow, Silent Knight Slow
1
Sescoa, Vertex, DCI, Franklin
Fast
2
Radionics Fast
3
Silent Knight Fast
4
Radionics, DCI, Franklin Slow
5
Universal High Speed
8
Radionics BFSK
DATA
ENTRY
CS RECEIVER 1 FORMAT
9
FBI 4/3/1
0
Radionics Modem 2
B
SIA
C
Ademco Point ID
D
Ademco Express
E
Pager
NOTE:
Modem IIe is available only in Direct
Address Programming. Central Station
Receiver 2 and 3 Formats can only be entered
in Direct Address Programming. See CS
Receiver Options.
(Direct Entry)
SEE WI FOR INFO
RCVR FORMAT (0)
GEM-RP1CAe2 Keypad: CS Format
(Direct Entry)
CENTRAL STATION
ACCOUNT #(____ )