X
GEM-P3200 Programming Instructions
L
NAPCO Security Systems
WI818D 08/00
!
Page 20
Key Fob Transmitters
(Press the
(
A
)
button to set cursor.)
Press the (
A
) button to set cursor. Keyfobs can be programmed as
“Arm/Disarm” devices (refer to WI752). For each Key Fob Transmitter, enter:
!
the Key Fob Transmitter number (01–08).
!
area number to which transmitter is assigned (1 or 2); enter 0 to disable key fob.
!
the 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters,
including leading “0”s, if any).
!
1-digit checksum number printed on the transmitter (enter all numbers and/or
letters, including leading “0”s, if any).
!
Aux-1 Option (see key fob aux 1 & aux 2 options).
!
Aux-2 Option (see key fob aux 1 & aux 2 options).
Note:
If the Key Fob is converted for Two Button “Emergency Use” (by
cutting an internal jumper), both top or bottom buttons must be
depressed to activate an alarms. In this case, the Aux-1 and Aux-2
cannot be programmed.
Press
J
to save. Press NEXT (
E
) button to proceed.
Key Fob Zone Assignment
(refer to display as shown on the
previous page: press the
(
F
)
button to go backwards.)
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 =
point 3; A2 = point 4. Up to 48 key fobs (using 1 button) or 24 key fobs (using 2 buttons) or 14 key fobs (using all 4
buttons) or any combination up to a maximum of 48 controlled zones can be assigned, providing multiple wireless panic
buttons on a system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zone
number with description/location.
To assign a key fob to a zone:
program the key fob as you would a transmitter, entering
the key fob's ID code, check sum and point number at the appropriate zone. The “Quick Method” is not allowed. The zone
may be hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output).
NOTE:
If
assigning a key fob to a zone, the “ON/OFF” buttons on the key fob will no longer arm/disarm the system. The key fob is
converted to a “panic only” device.
(Direct Entry)
KFOB01
AREA 0
000000
:0 0 0
DATA
ENTRY
AUX 1/AUX 2
OPTIONS
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
9
Panic
DATA
ENTRY
AUX 1/AUX 2
OPTIONS
A
Auxiliary
B
Instant
C
Aux. Output Toggle
D
Access on Aux.
Output
NOTE: Key fobs 1-8
report openings and
closings as Users 25-32.
GEM-RP2ASe2
Ke
yp
ad
:
Key
fob Transmitters
ZONE DESCRIPTIONS:
GEM-RP2ASe2 cannot be used to enter
Zone Descriptions. To enter Zone Descriptions you
must use the