7
Burglary Zone Wiring
NAPCO’s EZ Zone Doubling
TM
is simple. Each
terminal has 2 zones, use an E (2.2 K) type Zone
Doubling Resistor for the primary zone and a Z
(3.9 K) type Zone Doubling Resistor for the
secondary zone.
Wire zones as shown in the wiring diagram (pg.
27). All resistors must be installed, even if the
zone is not used. If required, unsupervised
open
circuit devices may be used instead of closed
circuit devices. Program the zone as an
Open
Circuit Zone [06] (Zone Doubling Resistor re-
quired). If necessary, use the voltage chart
below to verify proper voltages.
Fire Zone Wiring
Wire the Fire Zone as shown in the Wiring
Diagram in the back of this manual. An EOL
resistor must
be installed, even if the Fire Zone
is not used.
PGM Wiring
The PGM is a switched negative output that is
activated depending on the programming op-
tion(s) that have been selected [08], [23] - [25].
Connect the device controlled by the PGM
bPWR and the PGM terminal
(maximum load of 50 mA).
.H\SDG 2SHUDWLRQ
Keypad zone LEDs indicate zone status.
ARMED, STATUS and
SYSTEM LEDs pro-
vide system status. The keypad sounder pro-
vides feedback beeps for correct and incorrect
entries.
Keypad Sounder
3
QUICK BEEPS
Panel Armed (System ON)
Chime ON
Fault Find Mode ON
Keypad Sounder ON
Zone Bypassed
6
QUICK BEEPS
Panel Disarmed (System OFF)
Chime OFF
Fault Find Mode OFF
Keypad Sounder OFF
Zone Un-Bypassed
1
SECOND
-
STEADY TONE
Incorrect Code Entered
Invalid key entry
4
LONG BEEPS
(
PRIORITY CONDITION
)
1. Entering an Arm Code with a faulted zone
(Not an Auto-Bypass Reentry Zone).
2. Entering an Arm Code when the Bell or
PGM is ON (Bell and PGM will turn OFF).
3. Arming with the Fire LED ON - reset re-
quired. Press the
key.
Terminals
Primary
Secondary
3&4
Zone 1
Zone 4
5&4
Zone 2
Zone 5
6&7
Zone 3
Zone 6
TABLE
2 EZ Z
ONE
D
OUBLING
TM
Fire Zone Normal
13.0V
Fire Trouble
13.8V
Fire
0.0 V
TABLE
4 V
OLTAGE AT
F
IRE
Z
ONE
(Terminals 8&9)
Primary and Secondary zones normal
1.9 V
Secondary open
2.5 V
Primary open
3.2 V
Primary and Secondary open
5.0 V
Primary and Secondary shorted (Sys. Trbl 7-
Zone Trbl)
0.0 V
TABLE
3 V
OLTAGE AT
T
ERMINALS
3&4, 5&4, 6&7
Wi850a
page 7