10
WI850A GEM-P800 Installation Instructions
of 1234, program the 4-digit User 1 Code through
Dealer Programming [95]. User 1 Arm/Disarm
code is also used to program User Codes 2 - 8.
By default, the User 1 code cannot be re-
programmed by the user.
If it is necessary to change the User 1 code, it
can be changed through downloading or Dealer
keypad programming. From Dealer Program
Mode, change the U
ser 1 Code Lockout ([96-2]
LED=OFF) to disabled.
Entering User Program Mode
1. Enter
2. Enter User 1 Code (
)
(Default)
3. Press
While in User Program Mode the Armed, Status
and
System Trouble LEDs will continue to
flash, follow the example below to program
User 2’s code to 1923.
User Mode Programming Example:
1. Press
, Zone 2 LED will Flash
2. Enter
, Zone 2 LED
will continue to flash until the 4th digit is
entered. The keypad will beep 4 times
confirming a valid entry (Zone LED steady).
Deleting a User Code
Press the number of the User to be deleted, the
zone LED will be flashing indicating that the
user has been selected. Press the
key,
the LED associated with the user will now be
OFF.
Exiting User Program Mode
To exit User Program Mode press the
key.
*(03 &RPPDQGV
User Commands
Bell Test
Enter this command to turn on the Bell, keypad
sounder and keypad LEDs for 2 seconds. The
battery is tested during a Bell Test, and auto-
matically every *24 hours to ensure proper bat-
tery operation under load. The Alarm output
requires a battery in order to supply the specified
output. If the battery cannot sustain the load, a
low battery indication will be displayed. A battery
test is also performed on power-up after a 3
minute delay.
*A battery test occurs every 4 hours when
Household Fire [96-3] has been selected.
Easy Arm
Press this key to arm the panel. To disarm the
panel a valid Arm/Disarm code must be entered.
Requires
Easy Exit/Easy Arm [21-2] to be en-
abled.
Interior
Enter this command to bypass all
Exit/Entry
Follower Zones or Home/Away Zones (only if the
system is programmed exclusively for Home/
Away with Delay zones).
Instant
Enter this command before or after arming to
remove the entry delay on
Entry/Exit Zones. The
keypad ARMED LED will flicker rapidly. Faulting
a
Exit/Entry Zone will result in an immediate
alarm.
Chime ON/OFF
Enter this command to turn chime ON/OFF. The
ARMED
,
STATUS AND
SYSTEM TROUBLE
LED’s
WILL FLASH
.
ARM
ED
G E M I N I
STA
TUS
1
A 1 is displayed indicating
User 1 Code is programmed
and 2-8 are blank.
Zone LED Meaning
OFF
User Arm/Disarm Code not programmed
Flashing
User Arm/Code is currently being programmed
Steady
User Arm/Disarm Code has been programmed
TABLE
5
Z
ONE
L
ED
D
EFINITION
-U
SER
P
ROGRAM
M
ODE