14
WI850A GEM-P800 Installation Instructions
[15]Line Cut Time-to-Fail
Enable this feature by programming the de-
lay time required to declare a line cut failure.
Programming 000 will disable line cut detec-
tion.
[16]Wireless Supervisory Timer
A transmitter will send a transmission every
time it is tripped; when there is no activity,
the transmitter sends a supervisory transmis-
sion about once an hour. If the receiver does
not receive any signal (either a trip or a
status) from a transmitter in the time speci-
fied, a system trouble ‘RF Supervisory Fail-
ure' will be indicated at the keypad. Timer is
programmable from 1-26 hours; 0 means NO
supervision.
[17]Wireless Smoke Supervisory Timer
A smoke detector will send a transmission
every time it is tripped; when there is NO
activity, the smoke detector sends a supervi-
sory transmission about once an hour. If the
receiver does not receive a signal (either a
trip or a status) from a transmitter in the time
specified, a system trouble ‘RF Supervisory
Failure' will be indicated at the keypad. The
Supervisory timer is programmable from 1-8
hours; 0 means NO supervision.
[18]Test Timer Offset
Enter the time, in hours, that a Test Timer
will be reported after Dealer Mode has been
exited. With the default value of 12, the
test timer will be sent 12 hours after exiting
Dealer Mode. The test timer can also be
offset using NAPCO PCD3000 Download-
ing Software. On power up the test timer is
sent immediately. Follow the commands
below to offset the test timer using Quick-
loader Software:
From the Status Screen
Press
T
T
Select Miscellaneous Control
Select Test Timer Offset
Enter
New Test Timer Offset: 12 hours
Enter
X
to advance the test timer due
in time by 12 hours.
6\VWHP )HDWXUHV
[20]Keypad Features 1
(1) Enable Keypad Fire (
)
Additional Programming required:
Select reporting to Telco 1 [36-1] or Telco 3
[56-1].
(2) Enable Keypad AUX (
)
Additional Programming required:
Select reporting to Telco 1 [36-2] or Telco 3
[56-2].
(3) Enable Keypad Panic (
)
Additional Programming required:
Select reporting to Telco 1 [36-3] or Telco 3
[56-3].
(4) Enable Ambush - If enabled, the 8th
User Code will send an Ambush report when
entered to disarm the system.
Additional Programming required:
Program User 8 Arm/Disarm Code.
Select reporting to Telco 1 [36-2] or Telco 3
[56-2].
UL Installations: If Keypad Fire [20-1] is
enabled, the keypad must be mounted within
(3) three feet from the Control Panel.
[21]Keypad Features 2
(1) Audible Panic - Keypad Panic will not
turn the Bell on unless this option is pro-
grammed.
(2) Exit/Entry with Urgency - select to give
an audible indication of Exit and Entry times.
During the last 10 seconds of entry and exit
time, the keypad sounds a distinct sound to
indicate the premises must be left or the
panel must be disarmed.
(3) Display Bypassed (Armed) - Select to
display bypassed zones while the panel is
armed.
(4) Disable Code Entry Beeps - Program to
disable keypad beeping on valid code and
function entries.
Wi850a
page 14
Tuesday, September 16, 1997 08:01