3
6SHFLILFDWLRQV
&XUUHQW 9ROWDJH 5DWLQJV
Alarm Output ---------------------------Burg:
12 VDC, 2A (max.)
Fire:
12 VDC, 65 mA
Output Current Limiting --------------Burg/Fire: 2.25 A
AUX Power:
750 mA
Combined Standby Current: --------350 mA maximum
(Remote PWR, AUX Output, PGM)
4 Hour Standby:------------------------350 mA Standby Current
Bell Output 65 mA
(Using Rechargeable 12 VDC 4 AH BATTERY, minimal requirement)
24 Hour Standby: ----------------------120 mA Standby Current
Bell Output 95 mA
(Using Rechargeable 12 VDC 7 AH BATTERY, Optional)
7UDQVIRUPHU DQG %DWWHU\
Required Transformer: --------------NAPCO TRF12 OR
BASLER 16.5 VAC 20VA
Required Battery: ---------------------12V 4 AH Rechargeable
Change Battery every 5 years or as required
Maximum Charging Current: -------165 mA
Maximum Input Current: -------------2.58 A
/RRS &KDUDFWHULVWLFV
Loop Voltage: ------------------------- 5 Volts
Loop Current :-------------------------- Zones 1, 2, 3: 0.9 mA
Zones 4, 5, 6: 0.5 mA
Loop Resistance: --------------------- 100
Ω
per zone (max.)
'HYLFH 6SHFLILFDWLRQV
Max # keypads:------------------------ 4, GEM-RP8 current = 65 mA
Max # of receivers: ------------------- 2, GEM-RECV-XP8
current = 65 mA each
Max # of compatible
2-wire smoke detectors : ----------- 10
Max Keypad wire length : --------- 1000’ total wire length
0LVFHOODQHRXV
Housing Dimensions : -------------- 11"
x 12
1
/
8
"
x 3"
(28 x 30.8 x 7.6) HxWxD
Shipping Weight: -------------------- GEM-P800 5.5 lbs.
Operating Temperature: ------------ 0-49ºC (32-120°F)
Wi850a
page 3