Assembly
GEDA
®
3700 Z/ZP
Assembly Instructions
Page 48 of 60
ML034 GB 2017 / 11
6.8.4
Installing the mast tie
Mast tie for distance (B) 1.7 m to 2.8 m
(assembly 90° to the wall)
Item No.: 54390
Distance
A
≥
1.2 m
Variable
Distance
B
1.7 m - 1.8 m
fixed -
>
minimal wall distance
Distance
A
≥
1.7 m
Variable
Distance
B
2.7 m - 2.8 m
fixed -
>
maximal wall distance
Select distance (A) as wide as possible. The minimum distance of
both fastening plates is aligned against the distance between mast
and building.
For distances and tie forces, also refer to Chapter 3.11.1
Assembly example: Anchoring to the wall
Use the fixing bolt to install
the bracing tube
Firmly clamp the girder
using pipe clamps
Use close-tolerance bolts
and install the bracing tube
Tightening torque of the 1.5”- tube clamps =
50 Nm
(across flats = 22 mm)
B
A